ADuM2210/ADuM2211  
Data Sheet  
In the case of unipolar ac or dc voltage, the stress on the  
INSULATION LIFETIME  
insulation is significantly lower. This allows operation at higher  
working voltages while still achieving a 50-year service life. The  
working voltages listed in Table 10 can be applied while main-  
taining the 50-year minimum lifetime, provided the voltage  
conforms to either the unipolar ac or dc voltage cases. Any  
cross-insulation voltage waveform that does not conform to  
Figure 17 or Figure 18 should be treated as a bipolar ac  
waveform and its peak voltage should be limited to the 50-year  
lifetime voltage value listed in Table 10.  
All insulation structures eventually break down when subjected  
to voltage stress over a sufficiently long period. The rate of  
insulation degradation is dependent on the characteristics of the  
voltage waveform applied across the insulation. In addition to  
the testing performed by the regulatory agencies, Analog  
Devices carries out an extensive set of evaluations to determine  
the lifetime of the insulation structure within the ADuM221x.  
Analog Devices performs accelerated life testing using voltage  
levels higher than the rated continuous working voltage. Accel-  
eration factors for several operating conditions are determined.  
These factors allow calculation of the time to failure at the  
actual working voltage. The values shown in Table 10 summarize  
the peak voltage for 50 years of service life for a bipolar ac  
operating condition and the maximum CSA/VDE approved  
working voltages. In many cases, the approved working voltage  
is higher than a 50-year service life voltage. Operation at these  
high working voltages can lead to shortened insulation life in  
some cases.  
Note that the voltage presented in Figure 17 is shown as  
sinusoidal for illustration purposes only. It is meant to represent  
any voltage waveform varying between 0 V and some limiting  
value. The limiting value can be positive or negative, but the  
voltage cannot cross 0 V.  
RATED PEAK VOLTAGE  
0V  
Figure 16. Bipolar AC Waveform  
The insulation lifetime of the ADuM221x depends on the voltage  
waveform type imposed across the isolation barrier. The iCoupler  
insulation structure degrades at different rates, depending on  
whether the waveform is bipolar ac, unipolar ac, or dc. Figure 16,  
Figure 17, and Figure 18 illustrate these different isolation  
voltage waveforms.  
RATED PEAK VOLTAGE  
0V  
Figure 17. Unipolar AC Waveform  
Bipolar ac voltage is the most stringent environment. The goal  
of a 50-year operating lifetime under the ac bipolar condition  
determines the Analog Devices recommended maximum  
working voltage.  
RATED PEAK VOLTAGE  
0V  
Figure 18. DC Waveform  
Rev. A | Page 18 of 2  
 
 
 
 
 

与ADUM2211WSRWZ相关器件

型号 品牌 描述 获取价格 数据表
ADUM221N ADI 可靠的 5.0 kV rms 双通道数字隔离器、1 个反向通道和 7.8mm 爬电距离

获取价格

ADuM221N0BRWZ ADI 5.0 kV RMS Dual Channel Digital Isolators

获取价格

ADuM221N0BRWZ-RL ADI 5.0 kV RMS Dual Channel Digital Isolators

获取价格

ADUM221N1BRWZ ADI ADUM221N1BRWZ

获取价格

ADuM221N1BRWZ-RL ADI 5.0 kV RMS Dual Channel Digital Isolators

获取价格

ADUM221X ADI Digital Isolator Product Selection and Resource Guide

获取价格