ADuC7019/20/21/22/24/25/26/27
Parameter
Min
Typ
Max
Unit
Test Conditions/Comments
ANALOG OUTPUTS
Output Voltage Range_0
0 to
V
DACREF range: DACGND to DACVDD
DACREF
Output Voltage Range_1
Output Voltage Range_2
0 to 2.5
0 to
V
V
DACVDD
Output Impedance
2
Ω
DAC AC CHARACTERISTICS
Voltage Output Settling Time
Digital to Analog Glitch Energy
COMPARATOR
10
20
ꢀs
nV-sec
1 LSB change at major carry
Input Offset Voltage
Input Bias Current
Input Voltage Range
Input Capacitance
Hysteresis4, 6
15
1
mV
ꢀA
V
pF
mV
AGND
2
AVDD − 1.2
15
7
3
Hysteresis can be turned on or off via the
CMPHYST bit in the CMPCON register
100 mV overdrive and configured with
CMPRES = 11
Response Time
ꢀs
TEMPERATURE SENSOR
Voltage Output at 25°C
Voltage TC
780
−1.3
3
mV
mV/°C
°C
Accuracy
POWER SUPPLY MONITOR (PSM)
IOVDD Trip Point Selection
2.79
3.07
2.5
V
V
%
V
Two selectable trip points
Power Supply Trip Point Accuracy
POWER-ON RESET
GLITCH IMMUNITY ON RESET PIN3
WATCHDOG TIMER (WDT)
Timeout Period
Of the selected nominal trip point voltage
2.36
50
ꢀs
0
512
sec
FLASH/EE MEMORY
Endurance10
Data Retention11
10,000
20
cycles
years
TJ = 85°C
DIGITAL INPUTS
Logic 1 Input Current
Logic 0 Input Current
All digital inputs excluding XCLKI and XCLKO
VIH = VDD or VIH = 5 V
VIL = 0 V; except TDI on
0.2
−40
1
−60
ꢀA
ꢀA
ADuC7019/20/21/22/24/25
−80
10
−120
0.8
ꢀA
pF
VIL = 0 V; TDI, on ADuC7019/20/21/22/24/25
Input Capacitance
LOGIC INPUTS3
VINL, Input Low Voltage
VINH, Input High Voltage
LOGIC OUTPUTS
VOH, Output High Voltage
VOL, Output Low Voltage12
CRYSTAL INPUTS XCLKI and XCLKO
Logic Inputs, XCLKI Only
VINL, Input Low Voltage
VINH, Input High Voltage
XCLKI Input Capacitance
XCLKO Output Capacitance
All logic inputs excluding XCLKI and XCLKO
V
V
2.0
2.4
All digital outputs excluding XCLKI and XCLKO
ISOURCE = 1.6 mA
ISINK = 1.6 mA
V
V
0.4
1.1
1.7
20
V
V
pF
pF
20
Rev. A | Page 7 of 92