Data Sheet
ADP3335
SPECIFICATIONS
All limits at temperature extremes are guaranteed via correlation using standard statistical quality control (SQC) methods. Ambient
temperature of 85°C corresponds to a junction temperature of 125°C under pulsed full-load test conditions. Application stable with no
load. VIN = 6.0 V, CIN = COUT = 1.0 µF, TA = –40°C to +85°C, unless otherwise noted.
Table 1.
Parameter
Symbol
Conditions
Min
Typ
Max
Unit
OUTPUT
Voltage Accuracy1
VOUT
VIN = VOUT(NOM) + 0.4 V to 12 V
IL = 0.1 mA to 500 mA
TA = 25°C
–0.9
+0.9
%
VIN = VOUT(NOM) + 0.4 V to 12 V
IL = 0.1 mA to 500 mA
TA = 85°C
VIN = VOUT(NOM) + 0.4 V to 12 V
IL = 0.1 mA to 500 mA
TJ = 150°C
–1.8
–2.3
+1.8
+2.3
%
%
Line Regulation1
VIN = VOUT(NOM) + 0.4 V to 12 V
IL = 0.1 mA
TA = 25°C
IL = 0.1 mA to 500 mA
TA = 25°C
VOUT = 98% of VOUT(NOM)
IL = 500 mA
IL = 300 mA
IL = 50 mA
IL = 0.1 mA
0.04
0.04
mV/V
mV/mA
Load Regulation
Dropout Voltage
VDROP
200
140
30
370
230
110
40
mV
mV
mV
mV
10
Peak Load Current
Output Noise
ILDPK
VNOISE
VIN = VOUT(NOM) + 1 V
f = 10 Hz to 100 kHz, CL = 10 µF
IL = 500 mA, CNR = 10 nF
f = 10 Hz to 100 kHz, CL = 10 µF
IL = 500 mA, CNR = 0 nF
800
47
mA
µV rms
95
µV rms
GROUND CURRENT
In Regulation
IGND
IL = 500 mA
IL = 300 mA
IL = 50 mA
IL = 0.1 mA
VIN = VOUT(NOM) – 100 mV
IL = 0.1 mA
4.5
2.6
0.5
80
10
6
2.5
110
400
mA
mA
mA
µA
In Dropout
IGND
120
µA
IGNDSD
SD
In Shutdown
SHUTDOWN
0.01
1
µA
= 0 V, VIN = 12 V
VTHSD
Threshold Voltage
ON
OFF
SD
2.0
V
0.4
3
V
ISD
SD
1.2
µA
µA
Input Current
0 ≤
≤ 5 V
IOSD
Output Current in Shutdown
VIN = 12 V, VOUT = 0 V
0.01
5
1 VIN = 2.6 V to 12 V for models with VOUT(NOM) ≤ 2.2 V.
Rev. C | Page 3 of 16