ADP160/ADP161
Parameter
Symbol
UVLO
UVLORISE
UVLOFALL
UVLOHYS
OUTNOISE
Conditions
Min Typ
Max
Unit
UNDERVOLTAGE LOCKOUT
Input Voltage Rising
Input Voltage Falling
Hysteresis
2.19
V
V
1.60
100
105
100
80
mV
μV rms
μV rms
μV rms
dB
OUTPUT NOISE
10 Hz to 100 kHz, VIN = 5 V, VOUT = 3.3 V
10 Hz to 100 kHz, VIN = 5 V, VOUT = 2.5 V
10 Hz to 100 kHz, VIN = 5 V, VOUT = 1.2 V
100 Hz, VIN = 5 V, VOUT = 3.3 V
POWER SUPPLY REJECTION RATIO
PSRR
60
100 Hz, VIN = 5 V, VOUT = 2.5 V
65
dB
100 Hz, VIN = 5 V, VOUT = 1.2 V
72
dB
1 kHz, VIN = 5 V, VOUT = 3.3 V
50
dB
1 kHz, VIN = 5 V, VOUT = 2.5 V
50
dB
1 kHz, VIN = 5 V, VOUT = 1.2 V
62
dB
1 Accuracy when VOUT is connected directly to ADJ. When the VOUT voltage is set by external feedback resistors, the absolute accuracy in adjust mode depends on the
tolerances of resistors used.
2 Based on an end-point calculation using 0 ꢀA and 150 mA loads.
3 Dropout voltage is defined as the input-to-output voltage differential when the input voltage is set to the nominal output voltage. This applies only for output
voltages above 2.2 V.
4 Start-up time is defined as the time between the rising edge of EN to VOUT being at 90% of its nominal value.
5 Current limit threshold is defined as the current at which the output voltage drops to 90% of the specified typical value. For example, the current limit for a 3.0 V
output voltage is defined as the current that causes the output voltage to drop to 90% of 3.0 V or 2.7 V.
INPUT AND OUTPUT CAPACITOR, RECOMMENDED SPECIFICATIONS
Table 2.
Parameter
Symbol
CMIN
Conditions
Min
0.7
Typ
Max
Unit
μF
MINIMUM INPUT AND OUTPUT CAPACITANCE1
TA = −40°C to +125°C
TA = −40°C to +125°C
CAPACITOR ESR
RESR
0.001
0.2
Ω
1 The minimum input and output capacitance should be greater than 0.7 μF over the full range of operating conditions. The full range of operating conditions in the
application must be considered during device selection to ensure that the minimum capacitance specification is met. X7R and X5R type capacitors are recommended;
however, Y5V and Z5U capacitors are not recommended for use with any LDO.
Rev. 0 | Page 4 of 20