ADM1070  
FUNCTIONAL DESCRIPTION  
HOT CIRCUIT INSERTION  
Inserting circuit boards into a live –48 V backplane can cause large  
transient currents to be drawn as the board capacitance charges up.  
These transient currents can cause glitches on the system power  
supply and can permanently damage components on the board.  
Figure 2 shows how a plug-in module containing the ADM1070  
makes connection to the backplane supply. When the board is  
inserted, the –48 V and 0 V lines connect. This powers up the  
device with the voltage on VIN exceeding VLKO  
.
When the voltage at the UV/OV Pin exceeds undervoltage rising  
threshold (VUVR) of 0.91 V, it is now inside the operating volt-  
age window. It must stay inside this window for the duration of  
the power-on reset delay time, tPOR, which is dependent on the  
value of CT.  
The ADM1070 is designed to control the manner in which a  
board’s supply voltage is applied so that harmful transient currents  
do not occur and the board can be safely inserted or removed from  
a live backplane. Undervoltage, overvoltage, and overcurrent pro-  
tection are other features of the part. The ADM1070 ensures that  
the input voltage is stable and within tolerance before being applied  
to the dc-to-dc converter, which generates the low voltage levels  
required to power the on-board logic. One such converter is the  
Artesyn EXQ50. Go to www.artesyn.com for more information.  
When the device detects that the supply voltage is valid, it ramps  
up the gate voltage until the FET turns on and the load current  
increases. The ADM1070 monitors the level of the current flowing  
through the FET by sensing the voltage across the external  
sense resistor, RSENSE. When the sense voltage reaches 100 mV,  
the GATE Pin is actively controlled, limiting the load current.  
In this way, the maximum current permitted to flow through the  
PLUG-IN BOARD  
load is set by the choice of RSENSE  
.
ARTESYN  
EXQ50  
If a change in the level of the supply voltage causes UV/OV to  
fall below the undervoltage falling threshold of VUVF, or rise  
above the overvoltage rising threshold of VOVR, then the gate  
drive will be disabled.  
V
+
0V  
IN  
R1  
R2  
V
+
OUT  
LIVE  
BACKPLANE  
V
OUT  
ADM1070  
C
LOAD  
BOARD REMOVAL  
TRIM  
If the board is removed from a card cage, the voltage at the  
UV/OV pin falls to zero (i.e., outside operating range) and the  
gate drive is deasserted, turning off the FET.  
–48V  
V –  
IN  
R
FET  
SENSE  
CONTROLLING THE CURRENT  
The ADM1070 features a current limiting function that protects  
against short circuits or excessive supply currents. The flow of  
current through the load is monitored by measuring the voltage  
across the sense resistor, which is connected between the SENSE  
and VEE Pins. There are three different types of protection offered:  
Figure 1. Topology  
INITIAL STARTUP  
The ADM1070 hot swap controller normally resides on a remov-  
able circuit board and controls the manner in which power is  
applied to the board upon connection. This is achieved using a  
FET, Q1, in the power path. By controlling the gate voltage of  
the FET, the surge of current to charge load capacitance can be  
limited to a safe value when the board makes connection. Note  
that the ADM1070 can also reside on the backplane itself, and  
perform the same function from there.  
1. If the voltage across the sense resistor exceeds the circuit  
breaker limit voltage of 88 mV (rising) for the current limit  
on time (tLIMITON), then a current fault has occurred and the  
PWM cycle begins. The FET current is linearly controlled at  
a maximum of 100 mV/RSENSE (via the gate drive) during  
tLIMITON (see next section). The gate is then disabled for the  
duration tOFF. This PWM ratio, which will always be 3%, is  
0V  
given by tON/tOFF  
.
C
V
OUT  
LOAD  
R
16k⍀  
DROP  
A unique feature of the ADM1070 is the limited consecutive  
retry function. An internal fault counter keeps track of the  
number of successive PWM cycles that occur. The fault  
counter is incremented after every fault is detected. If the  
ADM1070 detects seven consecutive current faults, it is appar-  
ent that the fault is not a temporary one and the device  
latches itself off. The fault counter is cleared if a new tON  
timeout does not occur within 2 ϫ tOFF of the previous  
V
IN  
R1  
R2  
Q1  
R
GATE  
ADM1070  
LIVE  
BACKPLANE  
UV/OV  
SENSE  
SENSE  
TMER  
V
EE  
t
LIMITON timeout.  
–48V  
Figure 2. Circuit Board Connection  
REV. 0  
–9–  

ADM1070ARTZ-REEL 替代型号

型号 品牌 替代类型 描述 数据表
ADM1070ART-REEL7 ADI

完全替代

- 48 V Hot Swap Controller in SOT-23 with Linear Current Limiting
ADM1070ARTZ-REEL7 ADI

完全替代

- 48 V Hot Swap Controller in SOT-23 with Linear Current Limiting

与ADM1070ARTZ-REEL相关器件

型号 品牌 获取价格 描述 数据表
ADM1070ARTZ-REEL7 ROCHESTER

获取价格

1-CHANNEL POWER SUPPLY SUPPORT CKT, PDSO6, PLASTIC, MO-178AB, SOT-23, 6 PIN
ADM1070ARTZ-REEL7 ADI

获取价格

- 48 V Hot Swap Controller in SOT-23 with Linear Current Limiting
ADM1070EB ADI

获取价格

ADM1070 Hot Swap Controller Evaluation Kit Documentation
ADM1072 ADI

获取价格

Dual, USB 2.0 Full/Standby Power Controller with Supply Steering
ADM1072ARQ ADI

获取价格

Dual, USB 2.0 Full/Standby Power Controller with Supply Steering
ADM1072ARQ-REEL ADI

获取价格

暂无描述
ADM1072ARQ-REEL7 ADI

获取价格

IC 2-CHANNEL POWER SUPPLY SUPPORT CKT, PDSO16, QSOP-16, Power Management Circuit
ADM1073 ADI

获取价格

Full-Feature −48 V Hot Swap Controller
ADM1073ARU ADI

获取价格

Full-Feature −48 V Hot Swap Controller
ADM1073ARU-REEL ADI

获取价格

Full-Feature −48 V Hot Swap Controller