Preliminary Technical Data
ADE7169F16
ADE7169F16—SPECIFICATIONS
Table 1. (VDD = 3.3 V ꢀ5% AGND = DGND = 0 V% On-Chip Reference% XTAL = 32.768kHz% TMIN to TMAX = –40°C to +8ꢀ°C)
Parameter
Min
Typ
Max
Unit
Test Conditions/Comments
ENERGY METERING
MEASUREMENT ACCURACY1
Phase Error between Channels
(PF = 0.8 Capacitive)
(PF = 0.5 Inductive)
Active Energy Measurement Error2
0.05
0.05
0.1
°
°
Phase lead 37°
Phase lag 60°
Over a dynamic range of 1000 to 1 @25C
% of
reading
AC Power Supply Rejection2
Output Frequency Variation
DC Power Supply Rejection2
VDD = 3.3 V + 100 mV rms/120 Hz
IP = VP = 100 mV rms
0.01
%
VDD = 3.3 V 117 mV dc
IP = VP = 100 mV rms
Output Frequency Variation
Active Energy Measurement Bandwidth1, 2
Reactive Energy Measurement Error2
0.01
14
0.5
%
kHz
% of
reading
Over a dynamic range of 1000 to 1 @25C
Over a dynamic range of 100 to 1 @25C
VRMS Measurement Error2
0.5
% of
reading
kHz
% of
VRMS Measurement Bandwidth1, 2
IRMS Measurement Error2
14
0.5
Over a dynamic range of 1000 to 1 @25C
reading
kHz
IRMS Measurement Bandwidth1, 2
ANALOG INPUTS
14
VP – VN, IA – IN and IB – IN
Maximum Signal Levels
Input Impedance (DC)
Bandwidth (–3 dB)1
500 mV peak Differential input
TBD
kΩ
kHz
mV
14
ADC Offset Error2
1
Gain Error2
Current channel
Range = 0.5 V Full scale
Range = 0.25 V Full scale
Range = 0.125 V Full scale
Voltage channel
4
4
4
4
3
%
%
%
%
%
Current channel = 0.5V dc
Current channel = 0.25V dc
Current channel = 0.125V dc
Voltage channel = 0.5V dc
Gain Error Match2
CF1 and CF2 pulse output
Maximum output frequency
Duty cycle
Active High pulse width
FAULT Detection
21.1
50
90
kHz
%
ms
VP-VN = IAP-IN=500mV peak sine wave
If CF1 or CF2 frequency > 5.55Hz
If CF1 or CF2 frequency < 5.55Hz
Fault Detection Threshold
Inactive Input <> Active Input
6.25
6.25
%, of
larger
IA or IB active
IA or IB active
Input Swap Threshold
Inactive Input <> Active Input
% of
larger
Accuracy Fault Mode Operation
IA Active, IB = AGND
0.1
0.1
% of
reading
% of
Over a dynamic range of 500 to 1
Over a dynamic range of 500 to 1
IB Active, IA = AGND
reading
Fault Detection Delay
Swap Delay
3
3
Seconds
Seconds
ANALOG PERIPHERALS
Rev. PrD | Page 7 of 140