AD9551  
Input Receiver and Band Gap (Register 0x1A)  
Table 27.  
Address Bit  
Bit Name  
Description  
0x1A  
7
Receiver reset  
Input receiver reset control. This is an autoclearing bit.  
0 = normal operation (default).  
1 = reset input receiver logic.  
[6:2] Band gap voltage adjust  
Controls the band gap voltage setting from minimum (0 0000) to maximum (1 1111).  
Default is 0 0000.  
1
Enable receiver power-down  
Controls the option to power down the REFA and/or REFB receiver via Register 0x26[4]  
and Register 0x1E[4], respectively.  
0 = option disabled (default).  
1 = option enabled.  
0
Enable SPI control of band gap  
voltage  
Enables functionality of Bits[6:2].  
0 = the device automatically selects receiver band gap voltage (default).  
1 = Bits[6:2] define the receiver band gap voltage.  
DCXO Control (Register 0x1B to Register 0x1D)  
Table 28.  
Address  
Bit  
Bit Name  
Description  
0x1B  
7
Disable SPI control of DCXO  
tuning capacitor  
Disables functionality of Bits[5:0].  
0 = tuning capacitance defined by Bits[5:0].  
1 = the device automatically selects DCXO tuning capacitance (default).  
6
Enable SPI control of DCXO  
varactor  
Enables functionality of Register 0x1C and Register 0x1D[7:3].  
0 = the device automatically selects DCXO varactor (default).  
1 = varactor defined by Register 0x1C[7:0] and Register 0x1D[7:3].  
[5:0] DCXO tuning capacitor control  
Higher binary values correspond to smaller total capacitance, resulting in a higher  
operating frequency. Default is 00 0000.  
0x1C  
0x1D  
[7:0] DCXO varactor control  
[7:3] DCXO varactor control  
Bits[12:5] of the 13-bit varactor control word.  
Bits[4:0] of the 13-bit varactor control word. The default varactor control word is  
0 0000 0000 0000.  
2
1
0
Select 2× frequency multiplier  
Select/bypass the 2× frequency multiplier.  
0 = bypassed (default).  
1 = selected.  
DCXO bypass  
Select/bypass the DCXO.  
0 = selected (default).  
1 = bypassed.  
Unused  
Unused.  
Rev. B | Page 35 of 40  

与AD9551BCPZ相关器件

型号 品牌 获取价格 描述 数据表
AD9551BCPZ-REEL7 ADI

获取价格

Multiservice Clock Generator
AD9552 ADI

获取价格

Oscillator Frequency Upconverter
AD9552BCPZ ADI

获取价格

Oscillator Frequency Upconverter
AD9552BCPZ-REEL7 ADI

获取价格

Oscillator Frequency Upconverter
AD9552PCBZ ADI

获取价格

Oscillator Frequency Upconverter
AD9553 ADI

获取价格

Flexible Clock Translator for GPON, Base Station, SONET/SDH, T1/E1, and Ethernet
AD9553/PCBZ ADI

获取价格

Flexible Clock Translator for GPON, Base Station, SONET/SDH, T1/E1, and Ethernet
AD9553BCPZ ADI

获取价格

Flexible Clock Translator for GPON, Base Station, SONET/SDH, T1/E1, and Ethernet
AD9553BCPZ-REEL7 ADI

获取价格

Flexible Clock Translator for GPON, Base Station, SONET/SDH, T1/E1, and Ethernet
AD9554 ADI

获取价格

Quad PLL, Quad Input, Multiservice Line Card Adaptive Clock Translator