描述
Precision Instrumentation Amplifier

AD624ACHIPS 技术参数

是否无铅: 含铅是否Rohs认证: 不符合
生命周期:Active零件包装代码:DIP
包装说明:DIP,针数:16
Reach Compliance Code:unknown风险等级:5.78
放大器类型:INSTRUMENTATION AMPLIFIER最大平均偏置电流 (IIB):0.05 µA
标称带宽 (3dB):1 MHz最小共模抑制比:70 dB
最大输入失调电流 (IIO):0.035 µA最大输入失调电压:75 µV
JESD-30 代码:R-CDIP-T16JESD-609代码:e0
长度:19.05 mm湿度敏感等级:NOT SPECIFIED
负供电电压上限:-18 V标称负供电电压 (Vsup):-15 V
最大非线性:0.005%功能数量:1
端子数量:16最高工作温度:125 °C
最低工作温度:-55 °C封装主体材料:CERAMIC, METAL-SEALED COFIRED
封装代码:DIP封装形状:RECTANGULAR
封装形式:IN-LINE峰值回流温度(摄氏度):NOT SPECIFIED
认证状态:COMMERCIAL座面最大高度:5.08 mm
标称压摆率:5 V/us子类别:Instrumentation Amplifier
供电电压上限:18 V标称供电电压 (Vsup):15 V
表面贴装:NO温度等级:MILITARY
端子面层:TIN LEAD端子形式:THROUGH-HOLE
端子节距:2.54 mm端子位置:DUAL
处于峰值回流温度下的最长时间:NOT SPECIFIED最大电压增益:1000
最小电压增益:1标称电压增益:1000
宽度:7.62 mmBase Number Matches:1

AD624ACHIPS 数据手册

 浏览型号AD624ACHIPS的Datasheet PDF文件第7页浏览型号AD624ACHIPS的Datasheet PDF文件第8页浏览型号AD624ACHIPS的Datasheet PDF文件第9页浏览型号AD624ACHIPS的Datasheet PDF文件第11页浏览型号AD624ACHIPS的Datasheet PDF文件第12页浏览型号AD624ACHIPS的Datasheet PDF文件第13页 
AD624  
GROUNDING  
“inside the loop” of an instrumentation amplifier to provide the  
required current without significantly degrading overall perfor-  
mance. The effects of nonlinearities, offset and gain inaccuracies  
of the buffer are reduced by the loop gain of the IA output  
amplifier. Offset drift of the buffer is similarly reduced.  
Many data-acquisition components have two or more ground  
pins which are not connected together within the device. These  
grounds must be tied together at one point, usually at the sys-  
tem power supply ground. Ideally, a single solid ground would  
be desirable. However, since current flows through the ground  
wires and etch stripes of the circuit cards, and since these paths  
have resistance and inductance, hundreds of millivolts can be  
generated between the system ground point and the data acqui-  
sition components. Separate ground returns should be provided  
to minimize the current flow in the path from the most sensitive  
points to the system ground point. In this way supply currents  
and logic-gate return currents are not summed into the same  
return path as analog signals where they would cause measure-  
ment errors (see Figure 34).  
REFERENCE TERMINAL  
The reference terminal may be used to offset the output by up  
to ±10 V. This is useful when the load is “floating” or does not  
share a ground with the rest of the system. It also provides a  
direct means of injecting a precise offset. It must be remem-  
bered that the total output swing is ±10 volts, from ground, to  
be shared between signal and reference offset.  
+V  
S
SENSE  
V
+
IN  
IN  
ANALOG P.S.  
+15V –15V  
DIGITAL P.S.  
+5V  
C
C
AD624  
LOAD  
REF  
V
0.1 0.1  
F F  
0.1 0.1  
F F  
1F  
1F  
1F  
–V  
S
V
OFFSET  
AD711  
DIG  
COM  
+
DIGITAL  
DATA  
OUTPUT  
Figure 36. Use of Reference Terminal to Provide Output  
Offset  
AD583  
SAMPLE  
AND HOLD  
AD624  
AD574A  
ANALOG  
GROUND*  
SIGNAL  
GROUND  
When the IA is of the three-amplifier configuration it is neces-  
sary that nearly zero impedance be presented to the reference  
terminal. Any significant resistance, including those caused by  
PC layouts or other connection techniques, which appears  
between the reference pin and ground will increase the gain of  
the noninverting signal path, thereby upsetting the common-  
mode rejection of the IA. Inadvertent thermocouple connections  
created in the sense and reference lines should also be avoided  
as they will directly affect the output offset voltage and output  
offset voltage drift.  
OUTPUT  
REFERENCE  
*IF INDEPENDENT, OTHERWISE RETURN AMPLIFIER REFERENCE  
TO MECCA AT ANALOG P.S. COMMON  
Figure 34. Basic Grounding Practice  
Since the output voltage is developed with respect to the poten-  
tial on the reference terminal an instrumentation amplifier can  
solve many grounding problems.  
SENSE TERMINAL  
The sense terminal is the feedback point for the instrument  
amplifier’s output amplifier. Normally it is connected to the  
instrument amplifier output. If heavy load currents are to be  
drawn through long leads, voltage drops due to current flowing  
through lead resistance can cause errors. The sense terminal can  
be wired to the instrument amplifier at the load thus putting the  
IxR drops “inside the loop” and virtually eliminating this error  
source.  
In the AD624 a reference source resistance will unbalance the  
CMR trim by the ratio of 10 k/RREF. For example, if the refer-  
ence source impedance is 1 , CMR will be reduced to 80 dB  
(10 k/1 = 80 dB). An operational amplifier may be used to  
provide that low impedance reference point as shown in Figure  
36. The input offset voltage characteristics of that amplifier will  
add directly to the output offset voltage performance of the  
instrumentation amplifier.  
An instrumentation amplifier can be turned into a voltage-to-  
current converter by taking advantage of the sense and reference  
terminals as shown in Figure 37.  
V+  
(SENSE)  
OUTPUT  
CURRENT  
BOOSTER  
V
+
IN  
IN  
SENSE  
X1  
AD624  
+INPUT  
R
1
X
R
L
+V –  
V
I
L
(REF)  
AD624  
V–  
AD711  
A2  
–INPUT  
REF  
Figure 35. AD624 Instrumentation Amplifier with Output  
Current Booster  
V
V
LOAD  
IN  
40.000  
R
G
X
1 +  
I
=
=
L
Typically, IC instrumentation amplifiers are rated for a full  
±10 volt output swing into 2 k. In some applications, how-  
ever, the need exists to drive more current into heavier loads.  
Figure 35 shows how a current booster may be connected  
R
R
1
1
Figure 37. Voltage-to-Current Converter  
REV. C  
–10–  

与AD624ACHIPS相关器件

型号 品牌 描述 获取价格 数据表
AD624AD ADI Precision Instrumentation Amplifier

获取价格

AD624AD/+ ETC Amplifier. Other

获取价格

AD624ADZ ADI Precision Instrumentation Amplifier

获取价格

AD624B ADI Precision Instrumentation Amplifier

获取价格

AD624BD ADI Precision Instrumentation Amplifier

获取价格

AD624BDZ ADI High Precision, Low Noise Instrumentation Amplifier

获取价格