ABSO LUTE MAXIMUM RATINGS*
P aram eter
Conditions
Min Typ Max Units
Supply Voltage (+5 V dcSYS & FLD
DC Input Voltage (VIN MAX
DC Output Voltage (VOUT MAX
Clamp Diode Input Current (IIK
Clamp Diode Output Current (IOK
Output DC Current, per Pin (IOUT
)
–0.5
+6.0
+0.5
+0.5
+25
+25
+25
+50
+85
V
V
V
mA
mA
mA
mA
°C
)
Referred to +5 V dcSYS & FLD and 5 V RTNSYS & FLD Respectively –0.5
Referred to +5 V RTNSYS & FLD and 5 V dcSYS & FLD Respectively –0.5
)
)
For VI < –0.5 V or VI > 5 V RT NSYS & FLD +0.5 V
For VO < –0.5 V or VO > 5 V RT NSYS & FLD +0.5 V
–25
–25
–25
–50
–40
)
)
DC Current, VCC or GND (ICC or IGND
Storage T emperature (TST G
Lead T emperature (Soldering, 10 sec)
Electrostatic Protection (VESD
)
)
+300 °C
)
Per MIL-ST D-883, Method 3015
4.5
5
kV
*Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. T his is a stress rating only; functional operation of the device
at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum ratings for extended
periods may effect device reliability.
I/O CO NFIGURATIO NS AVAILABLE
P IN CO NFIGURATIO N
T he AD261 is available in several configurations. T he choice of
model is determined by the desired number of input vs. output
lines. All models have identical footprints with the power and
enable pins always being in the same locations.
1
2
3
4
5
6
7
8
S0
S1
S2
S3
S4
ENABLE
+5V dc
5V RTN
SYSTEM
SYS
SYS
P IN FUNCTIO N D ESCRIP TIO NS
SYS
P in
Mnem onic
Function
1–5*
6
7
S0 T hrough S4 Digital Xmt or Rcv from F0 T hrough F4
ENABLESYS
+5 V dcSYS
5 V RT NSYS
System Output Enable/T hree-State
System Power Supply (+5 V dc Input)
System Power Supply Common
Not Present On Unit
BOTTOM VIEW
8
9–14
15
16
17
5 V RT NFLD
+5 V dcFLD
ENABLEFLD
Field Power Supply Common
Field Power Supply (+5 V Input)
Field Output Enable/T hree-State
15
16
5V RTN
+5V dc
ENABLE
FLD
FLD
FLD
F0
F1
F2
17
FIELD
18
19
20
21
22
18–22* F0 T hrough F4 Digital Xmt or Rcv from S0 T hrough S4
F3
F4
*Function of pin determined by model. Refer to T able I.
O RD ERING GUID E
Model
Num ber
Isolation
Ratings
P ackage
D escription
P ackage
O ption
D escription
AD261AND-0
AD261AND-1
AD261AND-2
AD261AND-3
AD261AND-4
AD261AND-5
0 Inputs, 5 Outputs
1 Input, 4 Outputs
2 Inputs, 3 Outputs
3 Inputs, 2 Outputs
4 Inputs, 1 Output
5 Inputs, 0 Outputs
1.75 kV rms
1.75 kV rms
1.75 kV rms
1.75 kV rms
1.75 kV rms
1.75 kV rms
Plastic DIP
Plastic DIP
Plastic DIP
Plastic DIP
Plastic DIP
Plastic DIP
ND-22A
ND-22A
ND-22A
ND-22A
ND-22A
ND-22A
AD261BND-0
AD261BND-1
AD261BND-2
AD261BND-3
AD261BND-4
AD261BND-5
0 Inputs, 5 Outputs
1 Input, 4 Outputs
2 Inputs, 3 Outputs
3 Inputs, 2 Outputs
4 Inputs, 1 Output
5 Inputs, 0 Outputs
3.5 kV rms
3.5 kV rms
3.5 kV rms
3.5 kV rms
3.5 kV rms
3.5 kV rms
Plastic DIP
Plastic DIP
Plastic DIP
Plastic DIP
Plastic DIP
Plastic DIP
ND-22A
ND-22A
ND-22A
ND-22A
ND-22A
ND-22A
CAUTIO N
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection.
Although the AD261 features proprietary ESD protection circuitry, permanent damage may
occur on devices subjected to high energy electrostatic discharges. T herefore, proper ESD
precautions are recommended to avoid performance degradation or loss of functionality.
WARNING!
ESD SENSITIVE DEVICE
REV. 0