ACNT-H79B, ACNT-H79A, ACNT-H790
Data Sheet
Table 8. Package Characteristics
Typ. a
1.6
Parameter
Symbol
Min.
Max.
Unit
Test Conditions/Notes
Fig.
Input to Output Propagation
Delay
10%-10%
50%-50%
90%-90%
tPD10
tPD50
tPD90
tR/F
2.±
2.6
±.±
μs
μs
200 mV/μs step input
200 mV/μs step input
200 mV/μs step input
Step input
19
19
19
19
2.0
2.6
μs
Output Rise/Fall Time (10%-90%)
1.7
μs
VCM = 1 kV, TA = 25°C; Note b
Common Mode Transient Immunity
Power Supply Rejection
CMTI
15
20
kV/μs
PSR
–78
dB
1 Vpp 1 kHz sine wave ripple on
V
DD1, differential output; Note i
Power Supplies
VIN+ =±400 mV; see Note j
Input Side Supply Current
IDD1
IDD2
19
28
mA
20
Output Side Supply Current
7
11
10
mA 5 V supply
mA ±.± V supply
20
20
6.5
a.
b. See the Definitions section.
c. Gain temperature drift can be normalized and expressed as Temperature Coefficient of Gain (TCG) of –50 ppm/°C.
d. When FSR is exceeded, outputs saturate.
All Typical values are under Typical Operating Conditions at TA = 25°C, VDD1 = 5 V, VDD2 = ±.± V.
e.
f.
Because of the switched-capacitor nature of the input sigma-delta converter, time-averaged values are shown.
Under Typical Operating Conditions, part-to-part variation ±0.04 V.
g. Under Typical Operating Conditions, part-to-part variation ±1 dB.
h. Under Typical Operating Conditions, part-to-part variation ±1 dB.
i.
j.
Ripple voltage applied to VDD1 with a 0.1 μF bypass capacitor connected; differential amplitude of the ripple outputs measured. See Definitions section.
The input supply current decreases as the differential input voltage (VIN+ – VIN–) decreases.
Table 8. Package Characteristics
Parameter
Symbol
Min.
Typ.
Max.
Unit
Test Condition
Note
a b
Input-Output Momentary Withstand
Voltage
VISO
7500
Vrms
RH < 50%, t = 1 min., TA = 25°C
,
c
c
109
0.5
Resistance (Input-Output)
Capacitance (Input-Output)
RI-O
CI-O
VI-O = 500 VDC
f = 1 MHz
pF
a.
In accordance with UL 1577, each optocoupler is proof tested by applying an insulation test voltage ≥ 9000Vrms for 1 second (leakage detection current limit,
I-O ≤ 5μ A). This test is performed before the 100% production test for partial discharge (method b) shown in IEC/EN/DIN EN 60747-5-5 Insulation
Characteristic Table.
I
b. The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output continuous voltage rating.
For the continuous voltage rating, refer to the IEC/EN/DIN EN 60747-5-5 insulation characteristics table and your equipment level safety specification.
c.
This is a two-terminal measurement: pins 1–4 are shorted together and pins 5–8 are shorted together.
Broadcom
- 7 -