品牌 Logo 应用领域
博通 - BOARDCOM /
页数 文件大小 规格书
16页 979K
描述
Optical Isolation Amplifier in 15 mm Stretched SO-8 Package

ACNT-H79B 数据手册

 浏览型号ACNT-H79B的Datasheet PDF文件第1页浏览型号ACNT-H79B的Datasheet PDF文件第2页浏览型号ACNT-H79B的Datasheet PDF文件第3页浏览型号ACNT-H79B的Datasheet PDF文件第5页浏览型号ACNT-H79B的Datasheet PDF文件第6页浏览型号ACNT-H79B的Datasheet PDF文件第7页 
ACNT-H79B, ACNT-H79A, ACNT-H790  
Data Sheet  
Table ±. Insulation and Safety Related Specifications  
Table 3. Insulation and Safety Related Specifications  
Parameter  
Symbol  
Value  
Units  
Conditions  
Minimum External Air Gap  
(External Clearance)  
L(101)  
14.2  
mm  
Measured from input terminals to output terminals, shortest  
distance through air  
Minimum External Tracking  
(External Creepage)  
L(102)  
CTI  
15  
mm  
mm  
Measured from input terminals to output terminals, shortest  
distance path along body  
Minimum Internal Plastic Gap  
(Internal Clearance)  
0.5  
Through insulation distance, conductor to conductor, usually  
the direct distance between the photoemitter and  
photodetector inside the optocoupler cavity  
Tracking Resistance  
(Comparative Tracking Index)  
>±00  
IIIa  
V
DIN IEC 112/VDE 0±0± Part 1  
Isolation Group  
Material Group (DIN VDE 0110, 1/89, Table 1)  
Table 4. IEC/EN/DIN EN 60747-5-5 Insulation Characteristics (See Note)  
Description  
Symbol  
Value  
Units  
Installation classification per DIN VDE 0110/1.89, Table 1  
for rated mains voltage ≤ 150 Vrms  
I-IV  
I-IV  
I-IV  
I-IV  
I-IV  
for rated mains voltage ≤ ±00 Vrms  
for rated mains voltage ≤ 450 Vrms  
for rated mains voltage ≤ 600 Vrms  
for rated mains voltage ≤ 1000 Vrms  
Climatic Classification  
55/105/21  
Pollution Degree (DIN VDE 0110/1.89)  
Maximum Working Insulation Voltage  
2
VIORM  
2262  
Vpeak  
Input to Output Test Voltage, Method b  
VPR  
4242  
±619  
12000  
Vpeak  
Vpeak  
Vpeak  
V
IORM × 1.875 = VPR, 100% Production Test with tm = 1 sec, Partial Discharge < 5 pC  
Input to Output Test Voltage, Method a  
IORM × 1.6 = VPR, Type and Sample Test, tm = 10 sec, Partial Discharge < 5 pC  
VPR  
V
Highest Allowable Overvoltage (Transient Overvoltage, tini = 60 sec)  
VIOTM  
Safety-limiting values (Maximum values allowed in the event of a failure)  
Case Temperature  
Input Current  
Output Power  
TS  
175  
2±0  
600  
°C  
mA  
mW  
IS,INPUT  
PS,OUTPUT  
>109  
Insulation Resistance at TS, VIO = 500 V  
RS  
NOTE Insulation characteristics are guaranteed only within the safety maximum ratings, which must be ensured by  
protective circuits within the application.  
Broadcom  
- 4 -  

与ACNT-H79B相关器件

型号 品牌 描述 获取价格 数据表
ACNT-H870 BOARDCOM Precision Optically Isolated Voltage Sensor in a 15-mm Stretched SO-8 Package

获取价格

ACNT-H87A BOARDCOM Precision Optically Isolated Voltage Sensor in a 15-mm Stretched SO-8 Package

获取价格

ACNT-H87B BOARDCOM Precision Optically Isolated Voltage Sensor in a 15-mm Stretched SO-8 Package

获取价格

ACNV2601 AVAGO High Insulation Voltage 10 MBd Digital Optocoupler

获取价格

ACNV2601-000E AVAGO 1 CHANNEL LOGIC OUTPUT OPTOCOUPLER, 10Mbps, 0.500 INCH, ROHS COMPLIANT, PLASTIC, WIDE BODY

获取价格

ACNV2601-300E AVAGO High Insulation Voltage 10 MBd Digital Optocoupler

获取价格