DATA SHEET
AAT3673
1.6A Dynamic Battery Charger and Power Manager
Electrical Characteristics (continued)
VADP = 5V, TA = -25°C to +85°C; unless otherwise noted, typical values are TA = 25°C.
Symbol Description
Current Regulation
Conditions
Min
Typ
Max
Units
ILIM_ADP
ILIM_BAT
ICH_CC_ADP
ΔICH_CC_ADP
ICH_CC_ADP
ADP Current Limit (Fixed)
BAT_OUT Current Limit (Fixed)
ADP Charge Constant Current Charge Range
1.6
2.3
100
A
1600
12
mA
%
/
Constant Current Charge Current Regulation Tolerance ICH_CC_ADP = 1A
ADP Trickle Charge Current
-12
%
ICH_CC_ADP
ICH_TKL_ADP
10
VADPSET
VTERM
ADPSET Pin Voltage Regulation
TERM Pin Voltage Regulation
2
2
V
Constant Current Charge Current Set Factor: ICH_ADP
IADPSET
Termination Current Set Factor: ICH_TERM/ITERM
/
KI_CC_ADP
KI_TERM
29300
2000
AAT3673-3 Only
ICH_LO USB Low Level Charge Current (Fixed)
ICH_HI USB High Level Charge Current (Fixed)
Logic Control/Protection
VEN1 = VEN2 = 0
VEN1 = 0; VEN2 = 5V
85
450
100
500
mA
V
Input High Threshold
Input Low Threshold
1.6
VEN
0.4
0.4
STATx Pin Sinks
8mA
VSTATx
Output Low Voltage
Fast Charge (Trickle Charge + Constant Current +
Constant Voltage Charges Together) Timeout
Trickle Charge Timeout
TC
CCT = 0.1μF
7
Hour
Min
TTKL
VOVP
TC/8
VCO(REG)
+ 0.15
VCO(REG)
+ 0.1
VCO(REG)
+ 0.2
Battery Over-Voltage Protection Threshold
V
IOCP
TS1
TS2
Battery Charge Over-Current Protection Threshold
High Temperature Threshold
Low Temperature Threshold
In All Modes
Threshold
Threshold
100
30
60
% ICH_CC
% VBYP
28
58
32
62
TLOOP_IN
TLOOP_OUT
TLOOP_REG
Digital Thermal Loop Entry Threshold
Digital Thermal Loop Exit Threshold
Digital Thermal Loop Regulated Temperature
115
95
100
140
15
°C
Threshold
Hysteresis
TSHDN
Chip Thermal Shutdown Temperature
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
5
201881B
• Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • April 25, 2012