A29800 Series
Table 3. A29800 Bottom Boot Block Sector Address Table
Sector A18
A17
A16
A15
A14
A13
A12
Sector Size
(Kbytes /
Kwords)
Address Range
(x 16)
(x 8)
Address Range
00000h - 01FFFh
02000h - 02FFFh
03000h - 03FFFh
04000h - 07FFFh
08000h - 0FFFFh
10000h - 17FFFh
18000h - 1FFFFh
20000h - 27FFFh
28000h - 2FFFFh
30000h - 37FFFh
38000h - 3FFFFh
40000h - 47FFFh
48000h - 4FFFFh
Address Range
00000h - 03FFFh
04000h - 05FFFh
06000h - 07FFFh
08000h - 0FFFFh
10000h - 1FFFFh
20000h - 2FFFFh
30000h - 3FFFFh
40000h - 4FFFFh
50000h - 5FFFFh
60000h - 6FFFFh
70000h - 7FFFFh
80000h - 8FFFFh
90000h - 9FFFFh
SA0
SA1
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
0
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0
0
1
X
0
16/8
8/4
SA2
0
1
1
8/4
SA3
1
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
32/16
64/32
64/32
64/32
64/32
64/32
64/32
64/32
64/32
64/32
64/32
64/32
64/32
64/32
64/32
64/32
SA4
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
SA5
SA6
SA7
SA8
SA9
SA10
SA11
SA12
SA13
SA14
SA15
SA16
SA17
SA18
50000h - 57FFFh A0000h - AFFFFh
58000h - 5FFFFh B0000h - BFFFFh
60000h - 67FFFh C0000h - CFFFFh
68000h - 6FFFFh D0000h - DFFFFh
70000h - 77FFFh E0000h - EFFFFh
78000h - 7FFFFh F0000h - FFFFFh
Note:
Address range is A18: A-1 in byte mode and A18: A0 in word mode. See the “Word/Byte Configuration” section for more
information
Codes (High Voltage Method) table. In addition, when
verifying sector protection, the sector address must appear
on the appropriate highest order address bits. Refer to the
corresponding Sector Address Tables. The Command
Definitions table shows the remaining address bits that are
don't care. When all necessary bits have been set as
required, the programming equipment may then read the
corresponding identifier code on I/O7 - I/O0.
To access the autoselect codes in-system, the host
system can issue the autoselect command via the
command register, as shown in the Command Definitions
table. This method does not require VID. See "Command
Definitions" for details on using the autoselect mode.
Autoselect Mode
The autoselect mode provides manufacturer and device
identification, and sector protection verification, through
identifier codes output on I/O7 - I/O0. This mode is
primarily intended for programming equipment to
automatically match a device to be programmed with its
corresponding programming algorithm. However, the
autoselect codes can also be accessed in-system through
the command register.
When using programming equipment, the autoselect mode
requires VID (11.5V to 12.5 V) on address pin A9. Address
pins A6, A1, and A0 must be as shown in Autoselect
PRELIMINARY
(May, 2001, Version 0.0)
7
AMIC Technology, Inc.