描述
64K X 8 Bit CMOS 5.0 Volt-only, Uniform Sector Flash Memory

A29512-55 数据手册

 浏览型号A29512-55的Datasheet PDF文件第6页浏览型号A29512-55的Datasheet PDF文件第7页浏览型号A29512-55的Datasheet PDF文件第8页浏览型号A29512-55的Datasheet PDF文件第10页浏览型号A29512-55的Datasheet PDF文件第11页浏览型号A29512-55的Datasheet PDF文件第12页 
A29512 Series  
Autoselect Command Sequence  
The autoselect command sequence allows the host system  
to access the manufacturer and devices codes, and  
determine whether or not a sector is protected. The  
Command Definitions table shows the address and data  
requirements. This method is an alternative to that shown in  
the Autoselect Codes (High Voltage Method) table, which is  
intended for PROM programmers and requires VID on  
address bit A9.  
The autoselect command sequence is initiated by writing two  
unlock cycles, followed by the autoselect command. The  
device then enters the autoselect mode, and the system may  
read at any address any number of times, without initiating  
another command sequence.  
START  
Write Program  
Command  
Sequence  
Data Poll  
from System  
Embedded  
Program  
algorithm in  
progress  
Byte Program Command Sequence  
Programming is a four-bus-cycle operation. The program  
command sequence is initiated by writing two unlock write  
cycles, followed by the program set-up command. The  
program address and data are written next, which in turn  
initiate the Embedded Program algorithm. The system is not  
required to provide further controls or timings. The device  
automatically provides internally generated program pulses  
and verify the programmed cell margin. The Command  
Definitions table shows the address and data requirements  
for the byte program command sequence.  
When the Embedded Program algorithm is complete, the  
device then returns to reading array data and addresses are  
no longer latched. The system can determine the status of  
the program operation by using I/O7 or I/O6. See "Write  
Operation Status" for information on these status bits.  
Verify Data ?  
No  
Yes  
Last Address ?  
Yes  
Increment Address  
Any commands written to the device during the Embedded  
Program Algorithm are ignored. Programming is allowed in  
any sequence and across sector boundaries. A bit cannot be  
programmed from a "0" back to a "1 ". Attempting to do so  
may halt the operation and set I/O5 to "1", or cause the  
Programming  
Completed  
Note : See the appropriate Command Definitions table for  
program command sequence.  
Polling algorithm to indicate the operation was  
Data  
successful. However, a succeeding read will show that the  
data is still "0". Only erase operations can convert a "0" to a  
"1".  
Figure 1. Program Operation  
PRELIMINARY  
(November, 2001, Version 0.0)  
8
AMIC Technology, Inc.  

与A29512-55相关器件

型号 品牌 描述 获取价格 数据表
A29512-70 AMICC 64K X 8 Bit CMOS 5.0 Volt-only, Uniform Sector Flash Memory

获取价格

A29512-90 AMICC 64K X 8 Bit CMOS 5.0 Volt-only, Uniform Sector Flash Memory

获取价格

A29512A AMICC 64K X 8 Bit CMOS 5.0 Volt-only, Uniform Sector Flash Memory

获取价格

A29512A-55 AMICC 64K X 8 Bit CMOS 5.0 Volt-only, Uniform Sector Flash Memory

获取价格

A29512A-70 AMICC 64K X 8 Bit CMOS 5.0 Volt-only, Uniform Sector Flash Memory

获取价格

A29512A-90 AMICC 64K X 8 Bit CMOS 5.0 Volt-only, Uniform Sector Flash Memory

获取价格