A22TK  
Safety Precautions  
Be sure to read the precautions for all pushbutton switches in the website at www.ia.omron.com.  
damaged and may not operate properly.  
• Be sure to use the supplied Lock Ring. Otherwise, the switch may  
rotate and may not operate properly.  
DANGER  
Always confirm that safety functions are operational  
before stating operation. Wiring mistakes, setting  
mistakes, switch failure or other factors may prevent  
safety functions from operating. This may result in the  
machine continuing to operate, possibly resulting in  
human accidents.  
Others  
• Do not attempt to disassemble or modify the Switch. Doing so may  
cause the Switch to malfunction.  
• The durability of the Switch is greatly influenced by the switching  
conditions. Always test the switch under actual working conditions  
before application and use it in a switching circuit for which there  
are no problems with performance.  
• The user must not maintain or repair equipment incorporating the  
Switch. Contact the manufacturer of the equipment for any  
maintenance or repairs required.  
CAUTION  
If the Operation Unit is separated from the Socket Unit,  
the equipment will not stop, creating a hazardous  
condition.  
Secure the lever on the Socket Unit by using the A22Z-  
3380 Lock Plate so that the Operation Unit cannot be  
easily separated from the Socket Unit.  
Precautions for Correct Use  
Operating Environment  
• This Switch is designed for use indoors.  
Using the Switch outdoors may damage it.  
(Refer to “Mounting the Lock Plate” at the right.)  
• Do not use the Switch where corrosive gases (e.g., H2S, SO2, NH3,  
HNO3, or CI2) are present or in locations subject to high  
temperature and humidity. Doing so may result in damage to the  
Switch as a result of contact failure or corrosion.  
• Do not use the Switch in any of the following locations.  
• Locations subject to extreme temperature changes  
• Locations subject to high humidity or condensation  
• Locations subject to excessive vibration  
[Used in combination with a Slide Key]  
The machine may operate, possibly causing injury.  
Do not disable safety function by using a spare door  
switch operation key or spare key with the door  
open.  
[Used outside/inside hazardous area]  
The machine may operate, possibly causing injury.  
Do not disable safety function by using a spare key  
outside or inside the hazardous area.  
• Locations where metal dust, processing waste, oil, or chemicals  
may enter through the protective door  
• Locations subject to detergents, thinners, or other solvents  
Storage  
• Do not store the Switch where corrosive gases (e.g., H2S, SO2,  
NH3, HNO3, or Cl2) or dust is present, or in locations subject to high  
temperature or high humidity.  
Precautions for Safe Use  
Installation Environment  
• Do not use the switch in locations where explosive or flammable  
gasses may be present.  
Mounting  
• Do not tighten the mounting ring more than necessary using tools  
such as pointed-nose pliers. Doing so will damage the mounting  
ring. The tightening torque is 0.98 to 1.96 N·m.  
• Do not use the switch submerged in oil or water or in locations  
continuously subject to splashes of oil or water. Doing so may  
result in oil or water entering the switch.  
• Recommended panel thickness: 1 to 5 mm.  
Wiring  
Mounting the Lock Plate  
• Connect a fuse in series with the A22TK to protect it from  
shortcircuit damage. The value of the breaking current of the fuse  
must be calculated by multiplying the rated current by 150ꢀ to  
200ꢀ.  
1. Confirm that the lever on the Mounting Latch is on the side where  
the Operation Unit is secured and then insert the protrusion on the  
Lock Plate into the hole in the lever on the Mounting Latch.  
2. Press the hole on the Lock Plate onto the protrusion on the Mount-  
ing Latch until it clicks into place.  
When using the A22TK for an EN rating, use a 10-A fuse of type gI  
or gG that complies with IEC 60269.  
After mounting the Lock Plate, check that the lever does not move.  
• Always make sure that the power is turned OFF before wiring the  
Switch.  
Also, do not touch the terminals or other current-carrying ports  
while power is being supplied.  
2.  
Lock Plate  
Lever  
1.  
L
O
O
C
P
E
K
N
• Check the contact specifications before mounting the Switch  
Block. Use an NC contact for a safety circuit. It may not operate  
properly. Check the Switch Block for safe operation before use.  
• Check the operating specification before mounting the Operation  
Unit. It may not operate properly. Check the Operation Unit for safe  
operation before use.  
Operation Unit  
Mounting Latch  
Operating the Key  
Installation  
When rotating the key to the total travel position or free position,  
• Do not drop the Switch. Doing so may prevent the Switch from  
functioning to its full capability.  
the operating force must be 1.47 N·m max.  
• Make sure the Switch is mounted securely to prevent it from falling  
off. Otherwise injury may result.  
• Mount the Operation Key so that it will not come into contact with  
persons in the area when the door is opened and closed. Injury  
may result.  
• Do not use a Switch as a stopper. Otherwise, the switch may be  
12  