Proximity Sensors
972/973 Series
12 to 30 mm Diameter Harsh Environment Stainless Steel Sensors
4-Wire DC, 2, 4-Wire AC Types
LED INDICATOR GUIDE
LED Ref. No.
LED Indicator
Green On
Operation
1 (1 Dual LED)
N.O. output conducting
N.O. output shorted
Green Flashing
Red On
N.C. output conducting
N.C. output shorted
Red Flashing (2 LEDs)
Green On
2 (2 LEDs)
N.O. output conducting
N.C. output conducting
Output conducting
Red On
3 (1 LED)
Red On (1 LED)
N.O. Green On
N.O. Red On
4 (2 Dual LEDs)
N.O. output conducting
N.O. output shorted
N.C. Green On
N.C. Red On (2 [dual] LEDs)
Red On (1 LED)
N.C. output conducting
N.C. output shorted
5 (1 LED)
N.O. output conducting (N.O. output has no indicator)
CONNECTOR ORDER GUIDE
*High temperature/thermal cycle wash-
downs may cause loosening of cables to
sensor, due to material incompatibility.
Stainless steel or plastic cable nuts are sug-
gested in these applications. Contact your
local cable distributor for these devices.
Sensor
Type
Connector
Description
Cable
Catalog Listing
Length
Straight
Right Angle
4-wire DC Mini 4-pin standard key
6′
41108
—
12′
41109
—
4-wire DC Micro 4-pin standard key 6′
12′
6′
804000A09M020
804000A09M050
703000D02F060
703000D02F120
40902
804001A09M020
804001A09M050
2-wire AC Micro 3-pin dual slot
(973AA2JI-A5T-LF only)
703001D02F060
12′
6′
703001D02F120
2-wire AC Mini 3-pin standard key
—
—
—
—
12′
6′
40903
4-wire AC Mini 5-pin standard key
41307
12′
41308
SPECIFICATIONS, AC AND DC SENSORS
Sensor Type
4-wire DC
2-wire AC
2-wire AC
2-wire AC
4-wire AC
973AA311-C5T-LF1
4-wire AC
973AH311-D5T-LF
973AA3WI-C5T-LF1-037 973AH3WI-D5T-LF-037
Sensor Diameter
Output Style
12, 18, 30 mm
12 mm
N.O.
18 mm
N.O.
30 mm
N.O.
18 mm
18 mm
N.O. & N.C.,
NPN or PNP
N.O. & N.C.
N.O. & N.C.
Supply Voltage
10-30 VDC
0-200 mA
10 ȖA
93-132 VAC
5-100 mA
1.7 mA
93-132 VAC
5-500 mA
1.7 mA
93-132 VAC
5-500 mA
1.7 mA
93-132 VAC
5-500 mA
1.7 mA
93-132 VAC
5-500 mA
1.7 mA
Load Current, min-max.
Leakage Current, max.
Voltage Drop, max.
1.5 V
7.5 V
7.0 V
7.5 V
7.5 V
9.0 V (N.O.)
6.5 V (N.C.)
Inrush Current
—
500 mA
NO
2.7 A
NO
2.7 A
NO
2.7 A
NO
2.7 A
YES
Short Circuit Protection
YES
GENERAL SPECIFICATIONS
Repeatability
SENSING DISTANCE
Standard sensing distance is based on the
absence of any non-ferrous metals between
sensor face and ferrous target. If a build-up
of non-ferrous metals (chips, shavings, etc.)
occurs, it may be necessary to move the
ferrous target closer to the sensing face for
proper operation. The degree of reduced
sensing range depends on the size and lev-
elofbuild-upofthenon-ferrousmetals. Usu-
ally, minimal build-up causes no noticeable
effect on sensor performance. Worst case
conditions should be tested to determine
actual maximum achievable sensing range
before installation.
±1%
Switching Frequency
Hysteresis
20 Hz
2 to 15% of sensing distance
0° to 60°C (32° to 140°F)
NEMA 4X, 6P and 13
Temperature Range
Environmental Protection
Preleaded Style
12 ft. 16 gage STO or Supertrex
303 stainless steel
Housing Material
Honeywell ɀ MICRO SWITCH Sensing and Control ɀ1-800-537-6945 USA ɀ ⍣1-815-235-6847 International ɀ1-800-737-3360 Canada