91MCE Series
TECHNICAL SPECIFICATIONS
Parameter
Measure
Operating speed
0,05 mm to 1 m per second
120 ops per minute
30 ops per minute
> 100 Mohm @ 500 Vdc
300 Vac (EN60947-5-1)
Operating frequency – mechanical
Operating frequency – electrical
Insulation resistance
Rated voltage
Rated thermal current
Electrical rating
10A pre-leaded versions; 3A connector versions
ac 15 A 300; dc 13 Q300
Dielectric strength
1000 Vac for one minute between current carrying parts
2500 Vac for one minute between non-current carrying parts
5 million operations
Expected mechanical life
Expected electrical life
Operating temperature
Humidity
5 x 105 operations
-25 °C to 85 °C [ -13 °F to 185 °F] without the formation of ice
< 95 % RH
5 core, 0.75 mm2
Cable
Degree of protection
IP67
ELECTRICAL RATINGS
IEC 947-5-1 / EN 90947-5-1
Designation &
Rated operational current Ie (A) at rated operational voltage Ue
VA rating
Utilization Category
120 V
6
240 V
3
380 V
–
480 V
–
500 V
–
600 V
–
Make
Break
720
AC15
A300
7200
125 Vdc
0.55
250 Vdc
DC13
Q300
0.27
69
69
BAR CHARTS
Snap-action for plunger
actuators
Slow-action for plunger
actuators
Snap-action for side rotary
Slow-action for side rotary
PIN OUT – “Q” OPTION
Pin 1 & 2 – Normally Closed
Pin 3 & 4 – Normally Open
2
www.honeywell.com/sensing