ICS844251-14
FEMTOCLOCK™CRYSTAL-TO-LVDS CLOCK GENERATOR
AC Electrical Characteristics
Table 5A. AC Characteristics, VDD = 3.3V 5%, TA = 0°C to 70°C
Parameter Symbol
Test Conditions
FREQ_SEL = 0
FREQ_SEL = 1
Minimum Typical Maximum Units
145
580
187.5
750
MHz
MHz
fOUT
Output Frequency
156.25MHz,
Integration Range: 1.875MHz – 20MHz
0.53
0.45
ps
ps
RMS Phase Jitter, Random;
NOTE 1
tjit(Ø)
625MHz,
Integration Range: 1.875MHz – 20MHz
tR / tF
odc
Output Rise/Fall Time
Output Duty Cycle
20% to 80%
FREQ_SEL = 0
FREQ_SEL = 1
70
48
46
550
52
ps
%
%
54
NOTE: Electrical parameters are guaranteed over the specified ambient operating temperature range, which is established when the
device is mounted in a test socket with maintained transverse airflow greater than 500 lfpm. The device will meet specifications after
thermal equilibrium has been reached under these conditions.
NOTE 1: Please refer to Phase Noise Plots.
Table 5B. AC Characteristics, VDD = 2.5V 5%, TA = 0°C to 70°C
Parameter Symbol
Test Conditions
FREQ_SEL = 0
FREQ_SEL = 1
Minimum Typical Maximum Units
145
580
187.5
750
MHz
MHz
fOUT
Output Frequency
156.25MHz,
Integration Range: 1.875MHz – 20MHz
0.54
0.45
ps
ps
RMS Phase Jitter, Random;
NOTE 1
tjit(Ø)
625MHz,
Integration Range: 1.875MHz – 20MHz
tR / tF
odc
Output Rise/Fall Time
Output Duty Cycle
20% to 80%
FREQ_SEL = 0
FREQ_SEL = 1
70
48
46
550
52
ps
%
%
54
NOTE: Electrical parameters are guaranteed over the specified ambient operating temperature range, which is established when the
device is mounted in a test socket with maintained transverse airflow greater than 500 lfpm. The device will meet specifications after
thermal equilibrium has been reached under these conditions.
NOTE 1: Please refer to Phase Noise Plots.
IDT™ / ICS™ LVDS CLOCK GENERATOR
5
ICS844251BG-14 REV. A MAY 1, 2009