Programmable Attenuators
Specifications
SPECIFICATION
DESCRIPTION
Input Power Requirements
Environmental
ac
100 to 240 Vac, 50/60 Hz, 50 Watts
Operating Temperature:
Storage Temperature:
Humidity:
0 to +50°C
-4° to +167°F (-20° to +75°C)
96%
Altitude:
40,000' (12,192M)
IEEE-488 Bus (1)
Connector:
Protocols:
Indicators:
24-pin per IEEE-488.1
per IEEE-488.2
Remote (RMT), Listen (LSN), Talk (TLK), SRQ (SRQ)
RS-232 Bus (2)
Serial I/O
Connector:
Signals:
9-pin male D
TXD, RXD, RTS, CTS, DTR, GND
Baud Rates: 2400, 9600, 19200, and 38400
Data Bits:
8
Handshaking: None, RTS/CTS, XON/XOFF
Parity:
Indicators:
None, Odd, Even
Tx (Transmit) and Rx (Receive)
RS-422 BUS (3)
RS-485 Bus (4)
Connector:
Signals:
9-pin male D
TXD+, TDX-, RXD+, RTX-, RTS+, RTS-, CTS+, CTS-, and signal GND
Baud Rates: 2400, 9600, 19200, and 38400
Data Bits:
8
Handshaking: None, RTS/CTS, XON/XOFF
Parity:
Indicators:
None, Odd, Even
Tx (Transmit) and Rx (Receive)
Ethernet TC/IP
10 Base T Connector:
Console Connector:
Standard RJ45
9-pin male D
RF Characteristics(5)
See ordering guides (pg 128 through 130)
1. GPIB/IEEE-488ꢀmodel allows user-selectable addresses, Not included with Models with ethernet option.
2. RS-232 can be used with standard PC serial port for short and medium distances (up to approximately 50 ft).
3. RS-422, designed for very long distance communications (4000 ft) and & optimized as a single node protocol, typically with one device connected to a
single port.
4. RS-485, designed for very long distance communications (4000 ft) & optimized for multi-drop connections that can used to create a low cost network.
5. Refer to Individual data sheet for detailed specifications on internal programmables.
Ordering Guide...8310 Series with 4200 Programmables
Model No
Attenuation
Value (dB)
Frequency
Range (GHz)
Insertion Loss
(maximum)
SWR
No of
Attenuator
Model No.*
Connector
Type
Conn
Location
(Maximum) Channels
8310-136-F
8310-136-R
8310-136-2-F 63.75/0.25
8310-136-2-R 63.75/0.25
63.75/0.25
63.75/0.25
0.8-2.5
0.8-2.5
0.8-2.5
0.8-2.5
0.8-3.0
0.8-3.0
0.8-3.0
0.8-3.0
0.8-3.0
0.8-3.0
0.8-3.0
0.8-3.0
0.8-3.0
0.8-3.0
6.0
6.0
6.0
6.0
4.7
4.7
4.7
4.7
6.0
6.0
6.0
6.0
6.0
6.0
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1
1
2
2
1
1
2
2
1
1
2
2
3
4
4228-63.75
4228-63.75
4228-63.75
4228-63.75
4226-63
4226-63
4226-63
4226-63
4228-103
4228-103
4228-103
4228-103
4228-103
4228-103
N/F
N/F
N/F
N/F
N/F
N/F
N/F
N/F
N/F
N/F
N/F
N/F
N/F
N/F
Front
Rear
Front
Rear
Front
Rear
Front
Rear
Front
Rear
Front
Rear
Front/Rear
Front/Rear
8310-137-F
63/1
63/1
63/1
8310-137-R
8310-137-2-F
8310-137-2-R
8310-138-F
8310-138-R
8310-138-2-F
8310-138-2-R
8310-138-3-T
8310-138-4-T
63/1
103/1
103/1
103/1
103/1
103/1
103/1
*Refer to Individual data sheet for detailed specifications on internal programmables.
Add N to the end of the Model number for ethernet option, IEEE-488 bus not included with option.
130
5305 Spectrum Drive, Frederick, MD 21703-7362 s TEL: 301-846-9222, 800-638-2048 s Fax: 301-846-9116
web: www.aeroflex.com/weinschel s email: weinschel-sales@aeroflex.com
Revision Date: 8/15/11