Series 802 “Aqua Mouse”
3500 PSI Rated
LENGTH
+ 2.0/-0.0 (+50.8/ -0.0)
12 IN. (300 mm.) MIN.
A
B
C
D
E
F
A MAX.
SERIES 802 RECEPTACLE
SHIELDED JACKETED
CABLE
B MAX.
OVERMOLDED
STRAIN RELIEF
SERIES 802 PLUG
OPTIONAL
PROTECTIVE COVER
WITH POLYURETHANE
WIRE ROPE
RIGHT ANGLE CORDSETS
DIMENSIONS
LENGTH + 2.0/-0.0 (+50.8/ -0.0)
12 IN. (300 mm.) MIN.
A Max.
B Max. C Max. D Max.
E Max.
Shell
MASTER
KEY
Size In. mm. In. mm. In. mm. In. mm. In. mm.
5
6
LOCATED 180
C MAX.
2.000 50.80 .490 12.45 1.500 38.10 .490 12.45 1.650 41.91
2.500 63.50 .560 14.22 1.500 38.10 .560 14.22 1.650 41.91
2.500 63.50 .680 17.27 1.700 43.18 .680 17.27 1.700 43.2
2.500 63.50 .740 18.80 1.750 44.45 .740 18.80 1.750 44.45
2.500 63.50 .810 20.57 1.750 44.45 .810 20.57 1.750 44.45
2.750 69.85 .870 22.10 1.750 44.45 .870 22.10 1.750 44.45
3.000 76.20 .930 23.62 1.750 44.45 .930 23.62 1.750 44.45
3.500 88.90 1.120 28.45 1.750 44.45 1.120 28.45 1.750 44.45
3.750 95.25 1.180 29.97 2.000 50.80 1.180 29.97 2.000 50.80
FROM CABLE EXIT
7
8
9
E MAX.
10
12
14
15
How To Order Right Angle Cordsets
Insert the letter “R” after the End A or End B
Connector letter designator.
G
H
J
Example
D
MAX.
Straight cable 802-019-AC4Z16-4PA-72
Right Angle
802-019-ARCR4Z16-4PA-72
SERIES 802 HARSH ENVIRONMENT CORDSET SPECIFICATIONS
Thermoplastic Polyurethane, Black, UL 94 V-0 Rated, or Neoprene Rubber per
ASTM D2000
Cable Jacket Material
Cable Shield
Conductors
BAND-IT® Shield Termination Band
Tin-Coated Copper Braid, 90% Minimum Coverage
Silver Coated Stranded Wire, TFE Insulated, Per M22759/11
Stainless Steel
K
L
Current Rating
Up to 5 AMP Continuous Duty With #22 AWG Wire
500 VAC RMS sea level, 100 VAC RMS 70,000 feet
200 megohms minimum
-30° C. to +105° C.
Polyamide Overmold: 1 meter water immersion for 1 Hour per MIL-STD-810
Method 512 (IP68). Polyurethane overmold: 2500 PSI Hydrostatic Pressure
Test Voltage (Dielectric Withstanding Voltage)
Insulation Resistance
Operating Temperature
Immersion
Excellent Resistance to Most Solvents, Fuels, and Oils; Poor Resistance to
Strong Acids and Bipolar Solvents (Alcohol)
(8 Milliohms Mated Contacts) + (Wire Resistance)
50 dB minimum from 100MHz to 1000MHz.
Solvent Resistance, Polyamide Overmold
M
Electrical Resistance
Shielding Effectiveness
© 2007 Glenair, Inc.
CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
E-Mail: sales@glenair.com
E-19