Series 802 “Aqua Mouse”
3500 PSI Rated
LENGTH
+ 2.0/-0.0 (+50.8/ -0.0)
12 IN. (300 mm.) MIN.
A
B
C
D
E
F
A MAX.
SERIES 802 RECEPTACLE
SHIELDED JACKETED
CABLE
B MAX.
OVERMOLDED
STRAIN RELIEF
SERIES 802 PLUG
OPTIONAL
PROTECTIVE COVER
WITH POLYURETHANE
WIRE ROPE
RIGHT ANGLE CORDSETS
DIMENSIONS
LENGTH + 2.0/-0.0 (+50.8/ -0.0)
12 IN. (300 mm.) MIN.
A Max. B Max. C Max. D Max. E Max.
Shell
MASTER
Size In. mm. In. mm. In. mm. In. mm. In. mm.
KEY
LOCATED 180
FROM CABLE EXIT
C MAX.
2.00 50.8 .49 12.5 1.50 38.1 .49 12.5 1.65 41.9
2.50 63.5 .56 15.7 1.50 38.1 .56 15.7 1.65 41.9
2.50 63.5 .68 17.3 1.70 43.2 .68 17.3 1.70 43.2
2.50 63.5 .74 18.8 1.75 44.5 .74 18.8 1.75 44.5
2.50 63.5 .81 20.6 1.75 44.5 .81 20.6 1.75 44.5
2.75 69.9 .87 22.1 1.75 44.5 .87 22.1 1.75 44.5
3.00 76.2 .93 23.6 1.75 44.5 .93 23.6 1.75 44.5
3.50 88.9 1.12 28.5 1.75 44.5 1.12 28.5 1.75 44.5
3.75 95.3 1.18 30.0 2.00 50.8 1.18 30.0 2.00 50.8
5
6
7
8
9
E MAX.
G
H
J
10
12
14
15
How To Order Right Angle Cordsets
Insert the letter “R” after the End A or End B
Connector letter designator.
Example
D
MAX.
Straight cable 802-019-AC4Z16-4PA-72
Right Angle
802-019-ARCR4Z16-4PA-72
SERIES 802 HARSH ENVIRONMENT CORDSET SPECIFICATIONS
K
Thermoplastic Polyurethane, Black, UL 94 V-0 Rated, or Neoprene Rubber per
ASTM D2000
Cable Jacket Material
Cable Shield
Conductors
BAND-IT® Shield Termination Band
Nickel-Coated Copper Braid, 90% Minimum Coverage
Silver Coated Stranded Wire, TFE Insulated, Per M22759/11
Stainless Steel
L
Current Rating
Up to 5 AMP Continuous Duty With #22 AWG Wire
500 VAC RMS sea level, 100 VAC RMS 70,000 feet
200 megohms minimum
See Table I
-30° C. to +105° C.
Polyamide Overmold: 1 meter water immersion for 1 Hour per MIL-STD-810
Method 512 (IP68). Polyurethane overmold: 3500 PSI Hydrostatic Pressure
Excellent Resistance to Most Solvents, Fuels, and Oils; Poor Resistance to
Strong Acids and Bipolar Solvents (Alcohol)
(8 Milliohms Mated Contacts) + (Wire Resistance)
50 dB minimum from 100MHz to 1000MHz.
Test Voltage (Dielectric Withstanding Voltage)
Insulation Resistance
Contact Resistance
M
N
P
Operating Temperature
Immersion
Solvent Resistance, Polyamide Overmold
Electrical Resistance
Shielding Effectiveness
© 2006 Glenair, Inc.
CAGE Code 06324/0CA77
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
E-Mail: sales@glenair.com
E-19