Dimensions: [mm]
Recommended Land Pattern: [mm]
Electrical Properties:
Properties
Test conditions
100 MHz
Value
68
Unit Tol.
nH ±±5
min.
Inductance
L
Q-Factor
Q
100 MHz
8
1,7
0,5
Rated Current
DC Resistance
Self Resonant Frequency
IR ΔT = 20 K
RDC @ 20 °C
fres
180
1.2±
800
mA max.
Ω
max.
MHz min.
0,2 ±0,1
1,0 ±0,1
Certification:
RoHS Approval
Compliant [2011/6±/EU&201±/863]
REACh Approval
Halogen Free
Conform or declared [(EC)1907/2006]
Conform [JEDEC JS709B]
Conform [IEC 61249-2-21]
AEC-Q 200 Grade 1
Halogen Free
Scale - 30:1
Component Qualification
Automotive Approval
Released
Schematic:
General Information:
Do not use this part constantly beyond the Rated Current, as this will create excessive heat and can
harm the component
Ambient Temperature (referring
-±± up to +10± °C
to IR)
Operating Temperature
-±± up to +12± °C
< 40 °C ; < 7± 5 RH
1
Storage Conditions (in original
packaging)
Moisture Sensitivity Level (MSL)
Test conditions of Electrical Properties: +20 °C, 33 5 RH if not specified differently
Scale - 30:1
CHECKED
REVISION
DATE (YYYY-MM-DD)
GENERAL TOLERANCE
PROJECTION
METHOD
AdGa
001.000
2020-07-01
DIN ISO 2768-1m
DESCRIPTION
WE-MCI Multilayer Ceramic SMD
Inductor
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 94± - 0
www.we-online.com
eiSos@we-online.com
ORDER CODE
7847804680
SIZE/TYPE
BUSINESS UNIT
STATUS
PAGE
0402
eiSos
Valid
1/6
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.