6MBP50XFN120-50
IGBT Modules
Absolute maximum ratings
■
T C=25°C,T vj=25°C,V CC=15V unless otherwise specified
Items
Symbol
V CES
V SC
IC
Conditions
*1
*2
Min.
-
400
-
Max. Units
Collector-Emitter voltage
Short circuit voltage
1200
800
50
V
V
A
DC
ICP
-IC
Collector current
1ms
Duty=100%
-
-
100
50
A
A
*3
P tot
V RRM
IC
Total power dissipation
IGBT 1 device *4
Diode part
DC
-
-
-
-
416
-
-
W
V
A
Repetitive peak reverse voltage
Collector current
ICP
1ms
-
A
IF
Forward current of diode
Total power dissipation
Supply voltage of pre-driver
Input signal voltage
Alarm signal voltage
Alarm signal current
T vj warning signal voltage
T vj warning signal current
Virtual junction temperature
Operating virtual junction temperature
Operating case temperature
Storage temperature
-
-
-
20
A
W
V
V
V
P tot
V CC
V in
V ALM
IALM
V WNG
IWNG
T vj
T vjop
T c
T stg
T sol
V isol
M s
IGBT 1 device *4
-
-0.5
-0.5
-0.5
-
-0.5
-
-
*5
*6
*7
*8
*9
V CC+ 0.5
V CC
20
mA
V
V CC
20
*10
mA
°C
°C
°C
°C
°C
175
150
125
125
260
2500 Vrms
1.7
-
-
-20
-40
-
Solder temperature
Isolating voltage
Mounting torque of screws to heat sink
Mounting torque of screws to terminals
*11
*12
-
Mounting(M4)
Main terminals(M4)
1.3
-
Nm
Nm
M t
Notes
V
CES shall be applied to the input voltage between terminal P-(U,V, W) and (U,V, W)-N.
*1:
*2: In the case of the load inductance to be over 1μH.
Duty=150°C/R th(j-c)D/(IF×V F Max.)×100
P =150°C/R
*3:
*4:
tot
th(j-c)Q
V
CC shall be applied to the input voltage between terminal No.4 and 1, 8 and 5, 12 and 9,14 and 13.
*5:
V shall be applied to the input voltage between terminal No.3 and 1, 7 and 5, 11 and 9,16~18 and 13.
in
*6:
V
ALM shall be applied to the voltage between terminal No.2 and 1 , 6 and 5 , 10 and 9 , 19 and 13.
*7:
I
ALM shall be applied to the input current to terminal No. 2,6,10 and 19.
*8:
V
WNG shall be applied to the voltage between terminal No.15 and 13.
*9:
I
WNG shall be applied to the input current to terminal No.15.
*10:
*11: Immersion time 10±1sec. 1 time.
*12: Terminal to base, 50/60Hz sine wave 1 min. All terminals should be connected together during the test.
FM6M2014a
2023/03
2