Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Medium Performance Compact EMI Power Inlet Filter
ED Series
ED2
UL Recognized
CSA Certified
VDE Approved*
ED1 / ED1C
EC4 / ED4C
EC8 / ED8C
ED Series
Specifications
• Two element circuit provides medium attenuation
Maximum leakage current each Line to Ground:
@ 120 VAC 60 Hz:
@250 VAC 50 Hz:
.22 mA
.38 mA
• Available with an internal ground-circuit inductor
(C versions) to isolate equipment chassis from
power line ground at radio frequencies
Hipot rating (one minute):
Line to Ground:
Line to Line:
2250 VDC
1450 VDC
• Versions up to 15A*
• Similar to EEJ Series with alternative termination
options
Rated Voltage (max.):
250 VAC
50/60 Hz
1 to 15A*
Operating Frequency:
• See the EC Series for better differential mode
performance
Rated Current:
Operating Ambient Temperature Range
(at rated current I ):
-10°C to +40°C
In an ambient temperature (T ) higher than +40°C
r
a
Ordering Information
3 ED 1 C
the maximum operating current (I ) is calculated as
o
follows: I = I (85-Ta)/45
o
r
Ground Circuit Inductor
Omit if none
Available Part Numbers
1ED1
3ED1
6ED1
10ED1
15ED1
1ED2
3ED2
6ED2
1ED4
3ED4
6ED4
1ED8
3ED8
6ED8
Output Styles
1 – .250 [6.3] spade terminals
(back)
2 – .250 [6.3] spade terminals
(bottom)
15ED8
Ground Circuit Inductor Versions
6ED1C 6ED4C 6ED8C
4 – Wire leads (bottom)
8 – Wire leads (back)
10ED1C
ED Series
Current Rating
1, 3, 6, 10 or 15A
Electrical Schematic
LINE
LOAD
1
*15A versions are tested by Underwriters Laboratories
to US and Canadian requirements and are
VDE approved at 10A, 250VAC
Note 1: C versions only
144
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com