Z04
Standard
4 A Triacs
Main features
A2
A1
Symbol
IT(RMS)
Value
4
Unit
A
G
V
DRM/VRRM
600 to 800
3 to 25
V
IGT (Q )
mA
1
Description
A1
A2
G
The Z04 series is suitable for general purpose AC
switching applications. They can be found in
applications such as home appliances
(electrovalve, pump, door lock, small lamp
control), fan speed controllers,...
TO202-3
Different gate current sensitivities are available,
allowing optimized performances when controlled
directly from microcontrollers.
Order codes
Part Number
Marking
Z04xxyF(1)
Z04xxyF(1)
1. xx = sensitivity, y = voltage
Table 1.
Symbol
Absolute maximum ratings
Parameter
Value
Unit
Tamb = 25° C
IT(RMS)
RMS on-state current (full sine wave)
4
A
Tl = 30° C
t = 20 ms
t = 16.7 ms
F = 50 Hz
F = 60 Hz
tp = 10 ms
20
21
Non repetitive surge peak on-state current
(full cycle, Tj initial = 25° C)
ITSM
A
²
²
²
I t
I t Value for fusing
2.2
A s
Critical rate of rise of on-state current IG
2 x IGT , tr ≤ 100 ns
=
dI/dt
F = 120 Hz Tj = 125° C
20
A/µs
IGM
Peak gate current
tp = 20 µs
Tj = 125° C
Tj = 125° C
1.2
0.2
A
PG(AV)
Average gate power dissipation
W
Tstg
Tj
Storage junction temperature range
Operating junction temperature range
- 40 to + 150
- 40 to + 125
° C
May 2006
Rev 7
1/8
www.st.com
8