Philips Components
Product specification
Planar E cores
E64/10/50
Core halves for use in combination with an E core
AL measured in combination with a non-gapped core half, clamping force for AL measurements, 100 ±30 N,
unless stated otherwise.
AL
(nH)
AIR GAP
(µm)
GRADE
3C90
µe
≈78
TYPE NUMBER
630 ±3%(1)
1000 ±3%(1)
1600 ±5%
≈1100
≈660
≈385
≈225
≈170
≈0
E64/10-3C90-E630-E
E64/10-3C90-E1000-E
E64/10-3C90-A1600-E
E64/10-3C90-A2500-E
E64/10-3C90-A3150-E
E64/10/50-3C90
≈124
≈199
≈310
≈391
≈1820
≈78
2500 ±10%
3150 ±10%
14640 ±25%
630 ±3%(1)
1000 ±3%(1)
1600 ±5%
3F3
3F4
≈1100
≈660
≈385
≈225
≈170
≈0
E64/10-3F3-E630-E
E64/10-3F3-E1000-E
E64/10-3F3-A1600-E
E64/10-3F3-A2500-E
E64/10-3F3-A3150-E
E64/10/50-3F3
≈124
≈199
≈310
≈391
≈1650
≈78
2500 ±10%
3150 ±10%
13300 ±25%
630 ±3%(1)
1000 ±3%(1)
1600 ±5%
≈1100
≈660
≈385
≈225
≈170
≈0
E64/10-3F4-E630-E
E64/10-3F4-E1000-E
E64/10-3F4-A1600-E
E64/10-3F4-A2500-E
E64/10-3F4-A3150-E
E64/10/50-3F4
≈124
≈199
≈310
≈391
≈860
2500 ±10%
3150 ±10%
6960 ±25%
Note
1. Measured in combination with an equa -gapped core half, clamping force for AL measurements, 100 ±30 N.
Core halves for use in combination with a plate (PLT)
AL measured in combination with a plate (PLT), clamping force for AL measurements, 100 ±30 N.
AL
(nH)
AIR GAP
(µm)
GRADE
3C90
µe
≈78
TYPE NUMBER
630 ±3%
1000 ±3%
1600 ±5%
2500 ±10%
3150 ±10%
16540 ±25%
630 ±3%
≈1100
≈660
≈385
≈225
≈170
≈0
E64/10-3C90-A-630-P
E64/10-3C90-A-1000-P
E64/10-3C90-A-1600-P
E64/10-3C90-A-2500-P
E64/10-3C90-A-3150-P
E64/10/50-3C90
≈124
≈199
≈310
≈391
≈1790
≈78
3F3
≈1100
≈660
≈385
≈225
≈170
≈0
E64/10-3F3-A-630-P
E64/10-3F3-A-1000-P
E64/10-3F3-A-1600-P
E64/10-3F3-A-2500-P
E64/10-3F3-A-3150-P
E64/10/50-3F3
1000 ±3%
1600 ±5%
2500 ±10%
3150 ±10%
15050 ±25%
≈124
≈199
≈310
≈391
≈1630
1999 Dec 23
3