https://www.phoenixcontact.com/in/products/3211904
Fuse modular terminal block - PT 4-HESILED 24 (5X20) BU/
BK - 3211904
Technical data
General
Fire protection for rail vehicles (DIN EN 45545-2) R22
Fire protection for rail vehicles (DIN EN 45545-2) R23
Fire protection for rail vehicles (DIN EN 45545-2) R24
Fire protection for rail vehicles (DIN EN 45545-2) R26
HL 1 - HL 3
HL 1 - HL 3
HL 1 - HL 3
HL 1 - HL 3
Dimensions
Width
6.2 mm
56 mm
62.5 mm
70 mm
Length
Height NS 35/7,5
Height NS 35/15
Connection data
Conductor cross section solid min.
Conductor cross section solid max.
Conductor cross section flexible min.
Conductor cross section flexible max.
Conductor cross section AWG min.
Conductor cross section AWG max.
0.2 mm²
6 mm²
0.2 mm²
4 mm²
24
10
Conductor cross section flexible, with ferrule without plastic sleeve min. 0.25 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max. 4 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min.
Conductor cross section flexible, with ferrule with plastic sleeve max.
0.25 mm²
4 mm²
2 conductors with same cross section, stranded, TWIN ferrules with
plastic sleeve, min.
0.5 mm²
1 mm²
2 conductors with same cross section, stranded, TWIN ferrules with
plastic sleeve, max.
Connection method
Stripping length
Push-in connection
10 mm ... 12 mm
A4
Internal cylindrical gage
Standards and Regulations
Connection in acc. with standard
CSA
IEC 60947-7-3
V0
Flammability rating according to UL 94
Fire protection for rail vehicles (DIN EN 45545-2) R22
Fire protection for rail vehicles (DIN EN 45545-2) R23
Fire protection for rail vehicles (DIN EN 45545-2) R24
Fire protection for rail vehicles (DIN EN 45545-2) R26
HL 1 - HL 3
HL 1 - HL 3
HL 1 - HL 3
HL 1 - HL 3
Environmental Product Compliance
China RoHS
Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values
01/23/2019 Page 3 / 24