30KP33 thru 30KP400CA, e3
30kW Transient Voltage Suppressor
S C O T T S D A L E D I V I S I O N
SYMBOLS & DEFINITIONS
Definition
Symbol
Minimum Breakdown Voltage: The minimum voltage the device will exhibit at a specified current.
VBR
Working Peak Reverse Voltage: The maximum peak voltage that can be applied over the operating
temperature range.
Maximum Forward Voltage: The maximum forward voltage the device will exhibit at a specified current.
VRWM
VF
Maximum Leakage Current: The maximum leakage current that will flow at the specified voltage and
temperature.
IR
Capacitance: The capacitance of the TVS as defined @ 0 volts at a frequency of 1 MHz and stated in
picofarads.
C
OUTLINE AND CIRCUIT
TP – Pulse Time - sec
FIGURE 1
FIGURE 2
Pulse Wave Form
Peak Pulse Power vs. Pulse Time
DIMENSIONS
V(BR) - BREAKDOWN VOLTAGE – VOLTS
FIGURE 3
Typical Capacitance vs. Breakdown Voltage
Copyright © 2007
8-21-2007 REV K
Microsemi
Page 3
Scottsdale Division