5秒后页面跳转
3.0-VLVTTL PDF预览

3.0-VLVTTL

更新时间: 2022-06-03 06:49:33
品牌 Logo 应用领域
阿尔特拉 - ALTERA 开关
页数 文件大小 规格书
34页 836K
描述
This chapterdescribes the electric characteristics, switching characteristics,and I/O timing for Cyclone III devices. A glossary is also included for your reference

3.0-VLVTTL 数据手册

 浏览型号3.0-VLVTTL的Datasheet PDF文件第2页浏览型号3.0-VLVTTL的Datasheet PDF文件第3页浏览型号3.0-VLVTTL的Datasheet PDF文件第4页浏览型号3.0-VLVTTL的Datasheet PDF文件第6页浏览型号3.0-VLVTTL的Datasheet PDF文件第7页浏览型号3.0-VLVTTL的Datasheet PDF文件第8页 
Chapter 1: Cyclone III Device Datasheet  
1–5  
Electrical Characteristics  
DC Characteristics  
This section lists the I/O leakage current, pin capacitance, on-chip termination (OCT)  
tolerance, and bus hold specifications for Cyclone III devices.  
Supply Current  
Standby current is the current the device draws after the device is configured with no  
inputs or outputs toggling and no activity in the device. Use the Excel-based early  
power estimator (EPE) to get the supply current estimates for your design because  
these currents vary largely with the resources used. Table 1–4 lists I/O pin leakage  
current for Cyclone III devices.  
f
For more information about power estimation tools, refer to the PowerPlay Early Power  
Estimator User Guide and the PowerPlay Power Analysis chapter in the Quartus II  
Handbook.  
Table 1–4. Cyclone III Devices I/O Pin Leakage Current (1), (2)  
Symbol  
Parameter  
Conditions  
Min  
Typ  
Max Unit  
II  
Input pin leakage current  
VI = 0 V to VCCIOMAX  
–10  
10  
A  
Tristated I/O pin leakage  
current  
IOZ  
VO = 0 V to VCCIOMAX  
–10  
10  
A  
Notes to Table 1–4:  
(1) This value is specified for normal device operation. The value varies during device power-up. This applies for all  
CCIO settings (3.3, 3.0, 2.5, 1.8, 1.5, and 1.2 V).  
V
(2) 10 A I/O leakage current limit is applicable when the internal clamping diode is off. A higher current can be the  
observed when the diode is on.  
Bus Hold  
Bus hold retains the last valid logic state after the source driving it either enters the  
high impedance state or is removed. Each I/O pin has an option to enable bus hold in  
user mode. Bus hold is always disabled in configuration mode.  
Table 1–5 lists bus hold specifications for Cyclone III devices.  
(1)  
Table 1–5. Cyclone III Devices Bus Hold Parameter (Part 1 of 2)  
V
CCIO (V)  
Parameter  
Condition  
1.2  
1.5  
1.8  
2.5  
3.0  
3.3  
Unit  
Min Max Min  
Max Min Max Min Max Min Max Min Max  
Bus-hold  
low,  
sustaining  
current  
VIN > VIL  
(maximum)  
8
12  
30  
50  
70  
70  
A  
A  
Bus-hold  
high,  
sustaining  
current  
VIN < VIL  
(minimum)  
–8  
–12  
–30  
–50  
–70  
–70  
July 2012 Altera Corporation  
Cyclone III Device Handbook  
Volume 2  

与3.0-VLVTTL相关器件

型号 品牌 描述 获取价格 数据表
3.0-VPCI ALTERA This chapterdescribes the electric characteristics, switching characteristics,and I/O timi

获取价格

3.0-VPCI-X ALTERA This chapterdescribes the electric characteristics, switching characteristics,and I/O timi

获取价格

3.0X8.5 ETC ERSATZDICHTUNGSSCHNUR

获取价格

3.12.1000-100 ETC Analog IC

获取价格

3.12.1000-115 ETC Analog IC

获取价格

3.12.1000-220 ETC Analog IC

获取价格