ELECTRICAL DATA AND ORDERING INFORMATION
MAXIMUM
VOLTAGE at
STATED
MAXIMUM
NON-REP.
TRANSIENT
CURRENT(5)
Inrp (8 x 20 µs)
MAXIMUM
CONTINUOUS
VOLTAGE
MAXIMUM
ENERGY(4)
(10 X 1000 µS)
TYPICAL
CAPACITANCE
AT 1kHz
VOLTAGE(3)
at 1 mA
CATALOG
NUMBERS(1)
CURRENT
RMS(2)
(V)
DC
(V)
V
(V)
I
(V)
(J)
(A)
(pF)
2322 ... .....
(A)
1050
1025
1025
1025
5.0
27.0
54.0
800
1750
3500
6000
10000
800
40
95
582 .381.
583 .381.
584 .381.
585 .381.
586 .381.
582 .421.
583 .421.
584 .421.
585 .421.
586 .421.
582 .461.
583 .461.
584 .461.
585 .461.
586 .461.
583 .481.
584 .481.
585 .481.
586 .481.
583 .511.
584 .511.
585 .511.
586 .511.
584 .551.
585 .551.
586 .551.
584 .621.
585 .621.
586 .621.
584 .681.
585 .681.
586 .681.
10.0
25.0
50.0
385
505
620
107.0
215.0
420.0
28.0
180
280
570
35
1025 100.0
1150
1120
1120
1120
5.0
10.0
25.0
50.0
56.0
1750
3500
6000
10000
800
85
420
460
560
615
680
750
112.0
225.0
430.0
29.0
165
250
510
30
1120 100.0
1290
1240
1240
1240
5.0
10.0
25.0
50.0
58.0
1750
3500
6000
10000
1750
3500
6000
10000
1750
3500
6000
10000
3500
6000
10000
3500
6000
10000
3500
6000
10000
75
115.0
230.0
440.0
59.0
150
225
450
65
1240 100.0
1290
1290
1290
10.0
25.0
50.0
116.0
233.0
450.0
60.0
145
220
400
62
485
510
640
670
780
820
1290 100.0
1355
1355
1355
10.0
25.0
50.0
118.0
235.0
460.0
127.0
255.0
510.0
140.0
283.0
566.0
155.0
310.0
620.0
135
220
400
120
180
320
105
165
280
80
1355 100.0
1500
1500
25.0
50.0
550
625
680
745
825
895
910
1000
1100
1500 100.0
1650
1650
25.0
50.0
1650 100.0
1815
1815
25.0
50.0
150
250
1815 100.0
Notes
1. Lists with products certified according to UL (E98144), VDE (40002622) and CSA (219883) are available at www.vishay.com or on request.
2. The sinusoidal voltage is assumed as the normal operating condition. If a non-sinusoidal voltage is present, type selection should be based
on multiplying the peak voltage by a factor of 0.707.
3. The voltage measured at 1 mA meets the requirements of “paragraph 4.3 of CECC specification 42000”.
The tolerance on the voltage at 1 mA is ±10%.
4. High energy surges are generally of longer duration. The maximum energy for one pulse of 10 × 1000 µs is given as a reference for longer
duration pulses. This pulse can be characterised by peak current (Ip) and pulse width t2 (virtual time of half Ip value, following “IEC 60060-2,
section 6” ). If Vp is the clamping voltage corresponding to Ip, the energy absorbed in the varistor is determined by the formula:
E = K × Vp × Ip × t2
where:
a) K is dependant on the value of t2 when the value of t1 is between 8 µs and 10 µs; see Peak Current as a Function of Pulse Width drawing.
5. A current wave of 8 x 20 µs (requirement of “paragraph B.2.10.1 of CECC specification 42000” ) is used as a standard for pulse current and