5.3
5.4
Test Conditions. Unless otherwise stated herein, inspections are performed in accordance with
those specified in MIL-PRF-55310. Process travelers identify the applicable methods,
conditions and procedures to be used. Examples of electrical test procedures that correspond to
MIL-PRF-55310 requirements are shown in Table 3.
Deliverable Data. The manufacturer supplies the following data, as a minimum, with each lot
of devices:
a. Completed assembly and screening lot travelers, including rework history and Certificate
of Conformance.
b. Electrical test variables data, identified by unique serial number.
c. Frequency-Temperature Slew plots, Radiographic data, Group C data and RGA data as
required by purchase order.
d. Traceability, component LAT, enclosure LAT and RLAT (if specifically requested on
the purchase order).
5.5
5.6
Discrepant Material. All MRB authority resides with the procuring activity.
Failure Analysis. Any catastrophic failure (no output, no input current) at Post Burn-In or after
will be evaluated for root cause. The customer will be notified after occurrence and upon
completion of the evaluation.
6. PREPARATION FOR DELIVERY
6.1
Packaging. Devices will be packaged in a manner that prevents handling, ESD and transit
damage during shipping.
CODE IDENT NO.
UNSPECIFIED TOLERANCES
SIZE
DWG NO.
REV.
SHEET
F
A
00136
N/A
DOC200103
8