Features
Applications
nꢀ BalancedꢀMini-TRIGARD™ꢀ
nꢀ 5ꢀmmꢀdiameter,ꢀ7.5ꢀmmꢀlongꢀ
nꢀ ULꢀRecognized
nꢀ Telecommunications
nꢀ Industrialꢀelectronics
nꢀ Commercialꢀelectronics
nꢀ Consumerꢀelectronics
nꢀ Automotive,ꢀaircraft,ꢀmilitaryꢀelectronics
nꢀ RoHSꢀcompliant*ꢀversionsꢀavailable
ꢀ2036ꢀSeriesꢀ-ꢀMiniatureꢀ3-PoleꢀGasꢀDischargeꢀTube
ꢀ
ꢀ
Characteristics
Test Methods per ITU-T K.12, IEEE C62.31 and IEC 61643-311 GDT standards.
Model No.
Characteristic
2036-07
2036-09
2036-15
2036-20
2036-23
2036-25
DC Sparkover ±20 % @ 100 V/s
75 V
90 V
150 V
200 V
230 V
250V
Impulse Sparkover (1)
100 V/µs
1000 V/µs
250 V
525 V
250 V
550 V
350 V
500 V
425 V
575 V
450 V
600 V
475 V
625 V
Model No.
Characteristic
2036-30
2036-35
2036-40
2036-42
2036-47
2036-60
DC Sparkover ±20 % @ 100 V/s
300 V
350 V
400 V
420 V
470 V
600 V
Impulse Sparkover (1)
100 V/µs
1000 V/µs
500 V
650 V
600 V
750 V
650 V
825 V
675 V
850 V
750 V
950 V
850 V
1100 V
(1)
Impulse Sparkover voltage is defined as typical values of distribution.
Impulse Transverse Delay..................1000 V/µs............................................................................... <75 ns
Insulation Resistance .........................100 V (50 V for Model 2036–07 & 2036-09)........................... >1010
Glow Voltage ......................................10 mA..................................................................................... ~70 V
Arc Voltage.........................................1 A .......................................................................................... ~10 V
Glow-Arc Transition Current............................................................................................................... <0.5 A
Capacitance........................................1 MHz..................................................................................... <2 pF
DC Holdover Voltage(2) .......................135 V, (52 V for Model 2036-07 & 2036-09,........................... <150 ms
80 V for Model 2036-15)
Ω
Impulse Discharge Current.................20000 A, 8/20 µs (3) ................................................................. 1 operation minimum
10000 A, 8/20 µs .................................................................... >10 operations
2000 A, 10/350 µs .................................................................. 1 operation
200 A, 10/1000 µs ................................................................. >300 operations
200 A, 10/700 µs ................................................................... >500 operations
Alternating Discharge Current............20 Arms, 1 s (3) ........................................................................ 1 operation minimum
10 Arms, 1 s ........................................................................... >10 operations
Storage Temperature.......................................................................................................................... -55 to +105 °C
Operating Temperature....................................................................................................................... -55 to +105 °C
Climatic Category (IEC 60068-1)........................................................................................................ 55/105/21
An optional Switch-Grade Fail-Short device is available. The optional Fail-Short assembly will activate at a temperature of 215 °C – 217 °C
to provide a high conductive path to ground in case of a thermal overload. GDTs equipped with the optional Fail-Short device should be
soldered either manually at a temperature that is below the activation temperature of the Fail-Short mechanism, or using a selective soldering
process that does not exceed 210 °C.
Notes:
•
•
•
•
•
•
•
UL recognized component, UL File E153537.
No model number marking on tube; date code and voltage only: month year digits, xxxV (e.g. 0209 400V).
The rated discharge current for Mini-TRIGARD™ Gas Discharge Tubes is the total current equally divided between each line to ground.
Sparkover limits after life ±25 %, IR >108Ω (-25 %,+30 % for Model 2036-07, 2036-09 and 2036-60).
Operating characteristics per RUS PE-80 and Telcordia GR 1361 available, contact factory.
Line to Line voltage is approximately 1.8 to 2 times the stated Line to Ground breakdown voltage.
At delivery AQL 0.65 Level II, DIN ISO 2859.
(2) Network applied.
(3) DC Sparkover may exceed ±25 % after discharge, but will continue to protect without venting.
*RoHSꢀDirectiveꢀ2002/95/ECꢀJan.ꢀ27,ꢀ2003ꢀincludingꢀannexꢀandꢀRoHSꢀRecastꢀ2011/65/EUꢀJuneꢀ8,ꢀ2011.ꢀ
Specificationsꢀareꢀsubjectꢀtoꢀchangeꢀwithoutꢀnotice.
Theꢀdeviceꢀcharacteristicsꢀandꢀparametersꢀinꢀthisꢀdataꢀsheetꢀcanꢀandꢀdoꢀvaryꢀinꢀdifferentꢀapplicationsꢀandꢀactualꢀdeviceꢀperformanceꢀmayꢀvaryꢀoverꢀtime.
Usersꢀshouldꢀverifyꢀactualꢀdeviceꢀperformanceꢀinꢀtheirꢀspecificꢀapplications.