15ACMEB_4 series
15W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated
AC-DC Converter
15 Watt
Universal input: 85~264VAC
Regulated output, low ripple
and noise
High efficiency up to 86%
Short circuit protection (SCP)
Ocer current protection
Over voltage protection
Meet EN60950, UL60950
Mounting: PCB Mounting,
Chassis Mounting, DIN Rail
Mounting
IEC60601-1, EN60601-1, ANSI/
AAMI ES60601-1, CAN/CSA-
C22.2 No. 60601-1 approval
(2xMOPP)
The 15ACMEB_4 series is a compact size power converter offered by
Gaptec. It features universal input voltage, taking both DC and AC input
voltage, low power consumption, high efficiency, high reliability, safer
isolation. Meets IEC60601-1, EN60601-1, ANSI/AAMI ES60601-1, CAN/
CSA-C22.2 No. 60601-1 standards (2xMOPP), and widely used in medical,
industrial, instruments, telecommunication and civil applications. For
harsh EMC environment, the application circuit in the datasheet is
strongly recommended.
Approval
Model*
Power
[W]
Output voltage
[V]
Output current
[mA, max]
Capacitive Load
[µF, max]
Efficiency
[@230VAC, %, typ]
CSA/CE/CB
CSA/CE/CB
CSA/CE/CB
CSA/CE/CB
CSA/CE/CB
15ACMEB_05S4
15ACMEB_12S4
15ACMEB_15S4
15ACMEB_18S4
15ACMEB_24S4
15
15
15
15
15
5
2800
1250
1000
833
8000
4000
3000
2000
800
73
83
83
84
86
12
15
18
24
625
* Add suffix CM for Chassis mounting with screw terminals (f.ex. 15ACMEB_05S4CM), see different package measurements.
Add suffix DR for Din-Rail mounting (f.ex. 15ACMEB_05S4DR).
Input specifications
Input voltage range
Input frequency*
Input current
Output specifications
85-264 VAC; 100-370 VDC
47~440Hz
Item
Test conditions
Full load
Min Typ
2
Max
Units
%
Output voltage
accuracy
115VAC
• 0.37A (max)
230VAC
• 0.22A (max)
Line regulation
Load regulation
Ripple & Noise
Full load
0.5
1
%
Inrush current
(<2ms, cold start)
115VAC
• 10A (typ)
230VAC
• 20A (typ)
%
20MHz bandwidth
(peak-peak value)
50
100
0.1
mV
Leakage current
0.1mA RMS typ./264VAC/60Hz
• 2A/250V • slow fusing
Recommended external
fuse**
Stand-by power
consumption
W
%
Min. load
0
*
Medical Certification Input frequency range 47-63 Hz
** Chassis mounting, DIN-Rail mounting package series include fuse.
Hold-up time
(full load)
• @230VAC input
• @115VAC input
80
15
ms
ms
* Ripple and noise are measured by “parallel cable” method, please see AC-DC
Converter Application Notes for specific operation.
Protection specifications
Short circuit
protection
Protection type:
Continuous, self-recovery
Over-voltage
protection
Protection type:
Note:
• 5VDC output: ≤7.5VDC
• 12/15VDC output: ≤20VDC
• 18VDC output: ≤25VDC
• 24VDC output: ≤30VDC
1. If the product is not operated within the required load range, the product
performance cannot be guaranteed to comply with all parameters in the datas-
heet;
2. Unless otherwise specified, parameters in this datasheet were measured under
the conditions of Ta = 25°C, humidity <75% with nominal input voltage and rated
output load;
3. All index testing methods in this datasheet are based on our Company’s corpo-
rate standards;
4. We can provide product customization service, please contact our technicians
directly for specific information;
5. Products are related to laws and regulations: see „Features“ and „EMC“;
6. Our products shall be classified according to ISO14001 and related environmen-
tal laws and regulations, and shall be handled by qualified units.
Over-current
protection
Protection type:
≥110%Io self-recovery
Example:
15ACMEB_05S4
15 = 15Watt; AC = AC-DC; MEB = series; 5Vout; S = Single Output;
4 = 4kVAC isolation
Page 1 of 5
15ACMEB_4 – Rev. 2020-1.1
Specifications subject to change without notice.
GAPTEC-Electronic GmbH & Co. KG
sales@gaptec-electronic.com – www.gaptec-electronic.com