15ACP_S Series
15W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated
AC-DC Converter
15 Watt
The 15ACP_S series features standard rail mounting, energy efficiency
and is highly cost-effective. The series offers stability and high noise
immunity especially for industrial control equipment, machinery and
other demanding environments for industrial equipment. This converter
offers a compact and light weight design with and standard rail installation
(35mm). Furthermore this series offers Easy Fuse Tripping due and a
built-in DC OK relay contact. The converter can be installed on TS-35/7.5
or TS-35/15.
High efficiency up to 83%
Universal AC input range
(90~264VAC)
Withstand 300VA surge input
for 5 sec.
Over voltage protection (OVP)
Over load protection (OLP)
Short circuit protection (SCP)
Wide operating ambient
temperature (-20°C~70°C)
100% full load burn-in test
Easy assembling from top side
PCB soldering side with
conformal coating
Common specifications
Short circut protection:
Temperature rise at full load:
Cooling:
Input specifications
Long-term mode, automatic recovery
40°C MAX
Input voltage range
Input frequency
AC current
90~264VAC
47~63Hz
Free air convection
-20°C~+70°C
230VAC
0.7A (max)
Operation temperature range:
Storage temperature range:
Storage humidity range:
Temperature coefficient:
MTBF (using MIL-HDBK-217F):
Power boost:
Inrush current
Cold start,
230VAC
• 120VAC
20A (typ)
• 230VAC
40A (typ)
-40°C ~+85°C
Leakage current
Input—output: <0.25mA
Input—PG: <3.5mA
< 95%
0.03%/°C MAX
+25°C >200,000 hours
150% of rated current
support
Output specifications
Item
Test conditions
Full load
Min
Typ
Max
3
Units
%
Parallel function:
Output voltage
accuracy
Safety standards:
UL60950-1 2nd Ed; IEC 60950-
1:2005(2nd Ed); EN60950-1:2006
Voltage adjustment
range
• 3.3V
• 5V
• 12V
• 24V
• 48V
3.1
3.5
V
V
V
V
V
4.75
11.4
14.25
22.8
5.25
12.6
15.75
25.2
Case material:
Heat-resistant Plastic (UL94-V0) and
metal
Dimensions (L*W*H):
Weight:
79×51×28mm
217g
Line regulation
Load regulation
Vin= min. to max. at
full load
1
%
0% to 100% load
2
%
Isolation specifications
Set-up time
(full load)
• @230VAC input
• @120VAC input
1
2
s
s
Item
Test condition
Min
Typ
Max
Units
VAC
Withstand voltage*
• Primary-Sec.: 10mA
• Primary-PG: 10mA
3000
1500
Hold-up time
(full load)
• @230VAC input
• @120VAC input
20
10
ms
ms
• Secondary-PG: 10mA 500
Overshoot and
undershoot
5
%
Isolation resistance
100
MΩ
Switching frequency
100
KHz
* Input-Output, tested for 1 minute, 500VDC and leakage current less than 1mA
* Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated
with a 0.1 uF & 10uF parallel capacitor.
Protection specifications
Over-load
protection
• 3.3V: 4.4~7.2A
• 5V: 3.3~5.4A
Protection type:
constant power
• 12V: 1.43~2.34A
• 15V: 1.1~1.8A
• 24V: 0.77~1.26A
Example:
15ACP_24S
15= 15Watt
AC= AC-DC
P= series
24= 24 Vout
S= single output
Over-voltage
protection
• 3.3V: 14.52~23.76W
• 5V: 16.5~27W
• 12V: 17.16~28.08W
• 15V: 16.5~27W
Protection type:
constant voltage
• 24V: 18.48~30.24W
Note:
1. All parameters NOT specially mentioned are measured at 230VAC input, rated
load and 25°C of ambient temperature.
Page 1 of 3
GAPTEC-Electronic GmbH & Co. KG
15ACP_S – Rev. 2017-1.0
sales@gaptec-electronic.com – www.gaptec-electronic.com
Specifications subject to change without notice.