Dimensions: [mm]
Recommended Land Pattern: [mm]
General Properties:
Type
Optocoupler Triac Random phase
Input
DC
DIP 6, SL-Type
Black
4
5
3
Package
10,75
1,6
Plastic Housing Color
2
6
5
Certification:
1
2
6
1
RoHS Approval
REACh Approval
Halogen Free
Halogen Free
Compliant [2011/65/EU&2015/863]
Conform or declared [(EC)1907/2006]
Conform [JEDEC JS709B]
10,15 ±0,3
3
4
Conform [IEC 61249-2-21]
40051484 [DIN EN IEC 60747-5-5 (VDE
VDE Approval
7,62 ±0,3
6,5 ±0,2
0884-5):2021-10; EN IEC 60747-5-5:2020]
1,3 ±0,1
Scale - 3:1
cULus Approval
CQC Approval
E513104 [UL 1577]
23001411305 [GB 4943.1-2022]
Schematic:
0,8 typ.
1
6
General Information:
Anode
Terminal
Operating Temperature
-40 °C up to +100 °C
-55 °C up to +125 °C
Storage Conditions (for single
parts)
2
5
6
1
2
3
Cathode
NC
Storage Conditions (in original
packaging)
< 40 °C ; < 75 % RH
1
5
4
Moisture Sensitivity Level (MSL)
3
4
NC
Terminal
Scale - 3:1
Product Marking:
Marking
3012
YWW
CHECKED
REVISION
DATE (YYYY-MM-DD)
GENERAL TOLERANCE
PROJECTION
METHOD
Marking - Date Code
ZAn
001.001
2024-03-14
DIN ISO 2768-1m
DESCRIPTION
WL-OCTR Optocoupler Triac
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
ORDER CODE
14230126301
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
SIZE/TYPE
BUSINESS UNIT
STATUS
PAGE
DIP 6
eiPal
Valid
1/13
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation, transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic
component which is used in electrical circuits that require high safety and reliability functions or performance.