描述
DC-DC Regulated Power Supply Module, 1 Output, 7W, Hybrid

110IMX7-03-9M 技术参数

是否无铅: 含铅是否Rohs认证: 不符合
生命周期:Obsolete包装说明:,
Reach Compliance Code:compliantECCN代码:EAR99
风险等级:5.8模拟集成电路 - 其他类型:DC-DC REGULATED POWER SUPPLY MODULE
最大输入电压:150 V最小输入电压:60 V
标称输入电压:110 VJESD-30 代码:R-XDMA-X9
JESD-609代码:e0最大负载调整率:1%
功能数量:1输出次数:1
端子数量:9最高工作温度:71 °C
最低工作温度:-40 °C最大输出电压:3.465 V
最小输出电压:2.805 V标称输出电压:3.3 V
封装主体材料:UNSPECIFIED封装形状:RECTANGULAR
封装形式:MICROELECTRONIC ASSEMBLY峰值回流温度(摄氏度):NOT SPECIFIED
认证状态:Not Qualified表面贴装:NO
技术:HYBRID温度等级:OTHER
端子面层:TIN LEAD端子形式:UNSPECIFIED
端子位置:DUAL处于峰值回流温度下的最长时间:NOT SPECIFIED
最大总功率输出:5 W微调/可调输出:YES
Base Number Matches:1

110IMX7-03-9M 数据手册

 浏览型号110IMX7-03-9M的Datasheet PDF文件第6页浏览型号110IMX7-03-9M的Datasheet PDF文件第7页浏览型号110IMX7-03-9M的Datasheet PDF文件第8页浏览型号110IMX7-03-9M的Datasheet PDF文件第10页浏览型号110IMX7-03-9M的Datasheet PDF文件第11页浏览型号110IMX7-03-9M的Datasheet PDF文件第12页 
Board Mountable  
DC-DC Converters  
IMX 7 Series  
Short Circuit Behaviour  
Connection in Series or in Parallel  
The current limit characteristic shuts down the converter  
whenever a short circuit is applied to its output. It acts self-  
protecting and automatically recovers after removal of the  
overload condition (hiccup mode).  
Connection in series:  
The outputs of single or double output units can be con-  
nected in series without any precautions, taking into consid-  
eration that the highest output voltage should remain below  
60 V for SELV operation.  
Thermal Considerations  
Connection in parallel:  
If a converter, mounted on a pcb, is located in free, quasi-  
stationary air (convection cooling) at the indicated maxi-  
mum ambient temperature TA max (see table: Temperature  
specifications) and is operated at its nominal input voltage  
and output power, the case temperature TC measured at the  
Measuring point of case temperature TC (see: Mechanical  
Data) will approach the indicated value TC max after the  
warm-up phase. However, the relationship between TA and  
TC depends heavily on the conditions of operation and inte-  
gration into a system. The thermal conditions are influenced  
by input voltage, output current, airflow, temperature of sur-  
rounding components and surfaces and the properties of  
the printed circuit board. TA max is therefore only an indica-  
tive value and under practical operating conditions, the am-  
bient temperature TA may be higher or lower than this value.  
Double outputs of the same converter with equal output  
voltage (e.g. 5V / 5V) can be put in parallel and will share  
their output currents almost equally. Parallel operation of  
single or double outputs of two or more converters with the  
same output voltage may cause start-up problems at initial  
start-up. This is only advisable in applications where one  
converter is able to deliver the full load current as e.g. re-  
quired in true redundant systems.  
Output Overvoltage Protection  
The outputs of single output units and -05-05- types are  
protected against overvoltages by a second control loop. In  
the event of an overvoltage on the output the unit will shut-  
down and attempt to restart approximately every 0.4 sec-  
onds. Double output units (with exception of the -05-05-  
types) are protected against overvoltages by a Zener diode  
across the second output. Under worst case conditions the  
Zener diode will short circuit. Since with double output units  
both outputs track each other the protection diode is only  
provided in one of the outputs. The main purpose of this fea-  
ture is to protect against possible overvoltages which could  
occur due to a failure in the feedback control circuit. The  
output overvoltage protection is not designed to withstand  
externally applied overvoltages.  
Caution: The case temperature TC measured at the  
Measuring point of case temperature TC (see: Mechani-  
cal Data) may under no circumstances exceed the speci-  
fied maximum value. The installer must ensure that un-  
der all operating conditions TC remains within the limits  
stated in the table: Temperature specifications.  
Typical Performance Curves  
Uo [V]  
Uo [V]  
05087  
05086  
13  
5.5  
12  
11  
10  
9
5.0  
4.5  
4.0  
3.5  
3.0  
8
7
Io total [A]  
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9  
0
0
0.2  
0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 Io [A]  
0.4  
Fig. 11  
Fig. 12  
Uo versus Io (typ) of single output units with Uo = 5.1 V.  
Uo versus Io (typ) of double output units, with both outputs  
in parallel.  
Uo1 [V]  
Uo1, Uo2 [V]  
05088  
13.5  
05039  
14  
13  
13.0  
12.5  
Io2 = 0.03 A  
Io2 = 0.3 A  
12  
11  
10  
Uo4  
Uo1  
12.0  
11.5  
11.0  
Io1  
Io1 nom  
[%]  
50  
75  
100  
125  
150  
0
25  
0.03  
0.10  
0.15  
0.25  
0.35 Io1 [A]  
0.05  
0.20  
Fig. 13  
Fig. 14  
Uo1 versus Io1 (typ) for various Io2 (2 × 12 V).  
Flexible load distribution on double outputs (2 × 12 V) with  
The cross load effect is negligible.  
load variation from 0...150% of Po1 nom on output 1. Output  
2 loaded with 25% of Po2 nom  
.
Edition 4/04.2001  
9/18  

与110IMX7-03-9M相关器件

型号 品牌 描述 获取价格 数据表
110IMX7-05-05-7M BEL DC-DC Regulated Power Supply Module, 2 Output, 7W, Hybrid, 2 INCH X 1 INCH, 10.50 MM HEIGH

获取价格

110IMX7-05-05-8 BEL 7-Watt DC-DC Converters

获取价格

110IMX7-05-05-8 POWER-ONE IMX7/IMS7 DC-DC Series Data Sheet 7-Watt DC-DC Converters

获取价格

110IMX7-05-05-8G BEL DC-DC Regulated Power Supply Module, 2 Output, 7W, Hybrid, ROHS COMPLIANT PACKAGE-9

获取价格

110IMX7-05-05-8M BEL DC-DC Regulated Power Supply Module, 2 Output, 7W, Hybrid

获取价格

110IMX7-05-05-8ZG BEL DC-DC Regulated Power Supply Module, 2 Output, 7W, Hybrid, ROHS COMPLIANT PACKAGE-14

获取价格