110E
Mechanical Encoder
Vishay Spectrol
ELECTRICAL SPECIFICATIONS
Output
2 - bit grey code, channel L leads channel R by 90
degrees electrically in the CW direction
4 bi - grey code, absolute electrical position output
Closed Circuit Resistance
Open Circuit Resistance
Contact Rating
5Ω maximum
100KΩ minimum
Resistance load 250mA at 28VDC
1.5mA at 115VDC
150mA at 14VDC
Switching Loads
Bounce
5ms/cycle at 15 RPM
1000VAC at sea level
Continuous
Dielectric Withstanding Voltage
Electrical Travel
Operating Speed
50 RPM maximum
MECHANICAL SPECIFICATIONS
ENVIRONMENTAL SPECIFICATIONS
Rotational Torque
Mechanical Travel
Panel Mounting Torque
Shaft Load Force
Shaft Pull Force
Terminals
3.5 oz - in (2.16 - 3.60 Ncm)
Temperature Range
Humidity
- 40°C to + 105°C
(Operating temperature)
- 55°C to + 120°C
Continuous
(Storage temperature)
7 lbs - in (1.13 Nm) maximum
10 lbs - in (1.13 Nm) maximum
10 lbs - in maximum
Per MIL-STD 202, Method
106C Insulation resistance
shall be 1 MΩ maximum of a
relative humidity 90% @ 25°C
Standard PC style, 3
terminals on 0.100”
(2.54mm) grid - in - line
perpendicular or parallel
to shaft. Solder hook
available on 0.200” grid
Shock
Per MIL-STD 202,
Method 213, Test
Condition G consisting
of 1 MIL-STD
Molded Construction
Rotational Life
Molding compound
used for housing/bushing and
shaft has a UL94V - 2 rating
PACKAGING
100,000 detented cycles
at rated load typical (1
cycle = 720 degrees)
Box of 50 pieces
ORDERING INFORMATION
110E
MODEL
1
A
48
F
204P
P
BUSHING
SINGLE SHAFT FMS
CODED IN 64ths
2-4 - BIT GREY
CODE OPTIONS
110E
1 = at 9’0 clock
0 = None
A = 3/8 (9.53mm)
48 = 0.750”
56 = 0.875”
S:
204P = 4 cycles/rev
16 detents/rev
B: PC terminals straight
(horizontal mount)
C: PC terminals bent back
(vertical mount)
dia x 1/4 (6.35mm) long
G = 3/8 (9.53mm)
Slotted
F:
206P = 6 cycles/rev
24 detents/rev
dia x 3/8 (9.53mm) long
Flatted
209P = 9 cycles/rev
36 detents/rev
Type C - 30
P: Type B with
mounting bracket
D: Type C with
416P = 16 electrical
positions/rev
mounting bracket
S: Solder Hook
16 detents/rev
Hardware not included
SAP PART NUMBERING GUIDELINES
1
1
0
E
W
1
G
H
F
P
2
0
4
P
B
2
5
CODE OPTIONS
SPECIAL
PACKAGING
MODEL
BUSHING
SHAFT
LEADS
PEG
See the end of this data book for conversion tables
Document Number: 57089
Revision: 05-Aug-04
For technical questions, contact: sfer@vishay.com
www.vishay.com
137