Male Style 1/2 R High Temperature
Series 8577 – 3 rows (3 x 16) Inverted
Contact Design
and
Termination Length
Part Number
Performance classes according to DIN 41612
Number of
Contacts
Loading Description
a + b + c fully loaded
a + c fully loaded
a + c even loading
a loading only
II
I
48
32
10 8577 048 001 025
10 8577 048 001 026
10 8577 048 001 033
10 8577 048 001 027
10 8577 048 101 025
10 8577 048 002 025
10 8577 048 002 026
10 8577 048 002 033
10 8577 048 002 027
10 8577 048 102 025
10 8577 048 001 049
10 8577 048 001 050
10 8577 048 001 057
10 8577 048 001 051
10 8577 048 101 049
10 8577 048 002 049
10 8577 048 002 050
10 8577 048 002 057
10 8577 048 002 051
10 8577 048 102 049
16
2.9 mm (Y)
Straight
16
46 + 2
48
fully loaded + ground
a + b + c fully loaded
a + c fully loaded
a + c even loading
a loading only
32
16
4.5 mm (Y)
Straight
16
46 + 2
fully loaded + ground
NB: Alternative Prefix Variations Available: 16, please refer to Page 10.
Additional Plating & Loading Variations: Please contact your local AVX sales office or distributor.
LOADING DESCRIPTION DIMENSIONS
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
c
b
a
C
1
A EQ SP @ 2.54 [0.100] = B
1
GROUND
CONTACT
ROW A
48 contacts, rows a + b + c fully loaded
8.74
[0.344]
11.0
[0.433]
ROW B
ROW C
0.30
[0.012]
●
✕
●
●
✕
●
●
✕
●
●
✕
●
●
✕
●
c
b
a
E
2.80
[0.110]
F
D
DIA.
32 contacts, rows a + c fully loaded
11.0
[0.433]
✕
✕
✕
●
✕
●
✕
✕
✕
●
✕
●
✕
✕
✕
c
b
a
16 contacts, rows a + c even loading
✕
✕
●
✕
✕
●
✕
✕
●
✕
✕
●
✕
✕
●
c
b
a
5.95
[0.234]
A EQ SP @ 2.54 [0.100] = B
Y
2.54
[0.100]
2.54
[0.100]
ROW
A
16 contacts, row a loading only
For Y dimension
ROW
B
see contact design
ROW
C
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
c
b
a
0.30
[0.012]
2.84
[0.112]
DIA.
E
HOLE PATTERN
46 + 2 contacts, fully loaded
with ground in A1 & A16
Unit: millimeters (inches)
denotes ground pin
No. Contact Contact
Positions
Rows
A
B
C
D
E
F
48
3 (3 x 16)
15
38.10
44.70
47.29 49.99 54.91
(1.500) (1.760) (1.862) (1.968) (2.162)
105