Power entry modules without line filter
1067
www.schurter.com/pg05
IEC Appliance Inlet C14 or C18 with Voltage Selector and Fuseholder 1- or 2-pole
C14
C18
70° C
70° C
Description
References
- Panel Mount:
This type is Phase-out without alternate type
Last order possibility: 31.05.2011
Screw-on from front side, Appliance Inlet, protection class I or II, Vol-
tage Selectors
- Solder terminals or quick connect terminals
Weblinks
pdf-datasheet, html-datasheet, General Product Information, Approvals,
CE declaration of conformity, RoHS, CHINA-RoHS, Mating Connectors,
e-Shop, SCHURTER-Stock-Check, Distributor-Stock-Check, CAD-
Drawings, Accessories, Mounting instruction, Detailed request for
product
Approvals
- UL File Number: E88880
- CSA File Number: 1084381
Technical Data
Ratings IEC
Ratings UL/CSA
Dielectric Strength
10A / 250VAC; 50Hz
10A / 250VAC; 60Hz
> 3kVAC between L-N
> 1.5kVAC between L/N-PE
(1min/50Hz)
Appliance Inlet
C14 / C18 acc. to IEC 60320
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10A,
Protection Class I or II
1 or 2 pole, acc. to IEC 60127-6,
for fuse-links 5 x 20mm
Admissible power acceptance at hig-
her ambient temperature see derating
curves
Fuseholder
Allowable Operation Temp.
Degree of Protection
Protection Class
-25°C to 70°C
Power Acceptance @ Ta >
23°C
from front side IP 20 acc. to IEC 60529
Suitable for appliances with protection
class I or II acc. to IEC 61140
Solder terminals or quick connect ter-
minals
Voltage Selectors
Step switch, 2 positions
Terminal
Panel Thickness s
Material: Housing
:
PA6, black or grey, UL 94V-0
Dimensions
+0.2
- 0
27.2
50
24
52.5
5
2 2 0 - 2 4 0 V
110-120V
3
40
28
40
Length of the terminal please find at the order code configuration table
Connectors
1