MPA-1007THTP0 | MPA
POSITION SENSORS
≤ 35 mA 2)
≤ 500 Ω 3)
Power consumption
Max. load resistance
Min. load resistance
≥ 2 kΩ 4)
III
Protection class
2 mT
Required magnetic field sensitivity, typ.
Resolution, typ.
0.03 % FSR (max. ≥ 0.06 mm) 5)
0.5 mm 6)
Linearity error, typ.
Repeat accuracy, typ.
Sampling rate, typ.
0.06 % FSR (≥ 0.1 mm) 7)
1.15 ms 8)
✔
IO-Link
✔
Status indicator LED
Reverse polarity protection
Short-circuit protection
Ambient operating temperature
Shock and vibration resistance
EMC
✔
✔
–20 °C ... +70 °C
30 g, 11 ms/10 Hz ... 55 Hz, 1 mm
According to EN 60947-5-2 9)
Metal, Aluminum, Plastic
Housing material
Connection type
Cable with M8 male connector, 4-pin, 0.3 m 10)
PUR
Cable material
0.08 mm²
NRKH.E181493
Conductor cross-section
UL File No.
1)
Reverse-polarity protected, operation in short-circuit protected network: max. 8 A.
Without load.
2)
3)
4)
5)
6)
7)
8)
9)
Power Output, at 24 V.
Voltage output.
FSR: Full Scale Range; max. measuring range.
At 25 ° C, linearity error (maximum deviation) depending on response curve and minimal deviation function.
At 25 ° C, repeatability magnet movement in one direction.
Only in standard mode, not in IO-Link mode.
The analog measured value can deviate under transient conditions.
10)
Do not bend below 0 °C.
Classifications
27270104
27270104
27270104
27270104
27270104
27270104
27270104
27270104
EC002544
EC002544
ECl@ss 5.0
ECl@ss 5.1.4
ECl@ss 6.0
ECl@ss 6.2
ECl@ss 7.0
ECl@ss 8.0
ECl@ss 8.1
ECl@ss 9.0
ETIM 5.0
ETIM 6.0
2017-05-04 16:20:10 | Online data sheet
Subject to change without notice
MAGNETIC CYLINDER SENSORS | SICK
3