LUT3-910 | LUT3
LUMINESCENCE SENSORS
Ordering information
A
B
C
D
E
F
Type
LUT3-910
Part no.
1019285
Other models and accessories www.sick.com/LUT3
Detailed technical data
Features
30.4 mm x 53 mm x 80 mm
Dimensions (W x H x D)
Sensing distance
10 mm 1)
H
I
Rectangular
Housing design (light emission)
Light source
LED, Ultraviolet light 2)
375 nm
Wave length
2 mm x 6 mm
Light spot size
Receiving filters
Receiving range
Adjustment
J
KV 418 (standard)
450 nm ... 750 nm
Potentiometer
K
L
Light switching
Output function
1)
From front edge of lens.
2)
Average service life: 100,000 h at T = +25 °C.
U
M
N
O
P
Q
R
S
T
Mechanics/electronics
Supply voltage
12 V DC ... 30 V DC 1)
2)
Ripple
< 2 Vpp
< 60 mA 3)
1.5 kHz 4)
Power consumption
Switching frequency
Response time
350 µs 5)
PNP, NPN
Switching output
PNP: HIGH = VS– ≤ 3 V / LOW = approx. 0 V
Switching output (voltage)
1)
Limit values when operated in short-circuit protected network: max. 8 A.
2)
May not exceed or fall below U tolerances.
v
3)
4)
5)
6)
Without load.
With light/dark ratio 1:1.
Signal transit time with resistive load.
Reference voltage DC 50 V.
2
REGISTRATION SENSORS | SICK
Online data sheet | 2018-07-08 09:57:24
Subject to change without notice