描述
MULTIPLE LIGHT BEAM SAFETY DEVICES

1018172 数据手册

 浏览型号1018172的Datasheet PDF文件第1页浏览型号1018172的Datasheet PDF文件第2页浏览型号1018172的Datasheet PDF文件第3页浏览型号1018172的Datasheet PDF文件第4页浏览型号1018172的Datasheet PDF文件第6页浏览型号1018172的Datasheet PDF文件第7页 
M20S-02250A120, M20E-02250A120 | M2000 Standard  
MULTIPLE LIGHT BEAM SAFETY DEVICES  
Connection diagram  
+24 V DC  
1)  
x
y
y
k1 k2  
s
r
x
1
1
2
3
4
5
6
+24 V  
+24 V  
z
2
GND  
GND  
k1  
3
OSSD1  
OSSD2  
Sel1  
Test  
4
k2  
z
HRANGE  
5
Sel1  
6
Sel2  
Sel2  
Shield  
Shield  
S1  
M2000  
S33 S11 S12 S31 A1 13 23 31  
k1  
k2  
UE48-2OS2D2  
S34 S35 S21 S22 A2 14 24 32  
2)  
K1  
K2  
0 V  
E119932/01/2017-06-12  
3) PELV  
Task  
Connection of an M2000 Standard multi-beam photoelectric safety switch to UE48-2OS.  
Operating mode: with restart interlock and external device monitoring.  
Function  
When the light path is clear, the OSSD1 and OSSD2 outputs are live. The system is ready to switch on if K1 and K2 are de-ener-  
gized. By pressing S1 (button is pressed and released), the UE48-2OS is energized and its 13 - 14 and 23 - 24 contacts activate K1  
and K2. On interruption of one of the light beams, the UE48-2OS is de-energized by the OSSD1 and OSSD2 outputs and K1 and K2  
are deactivated.  
Fault analysis  
OSSD cross-circuits and short-circuits are detected and lead to the inhibited state (lock-out). The incorrect functioning of one of the  
K1 or K2 contactors will be detected and does not result in the loss of the shutdown function. Jamming of the S1 button will pre-  
vent the UE48-2OS from enabling.  
Comments  
1) Output circuits: These contacts are to be connected to the controller such that, with the output circuit open, the dangerous state  
is disabled. For categories 4 and 3, the integration must be dual-channel (x/y paths). Single-channel integration in the control (z  
path) is only possible with a single-channel control and by taking the risk analysis into account.  
2) The external device monitoring is only static.  
3) PELV as required in EN 60204-1 / 6.4  
The related operating instructions for the integrated devices must be observed.  
2017-06-14 08:06:28 | Online data sheet  
Subject to change without notice  
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK  
5

与1018172相关器件

型号 品牌 描述 获取价格 数据表
1018173 SICK MULTIPLE LIGHT BEAM SAFETY DEVICES

获取价格

1018174 SICK MULTIPLE LIGHT BEAM SAFETY DEVICES

获取价格

1018175 SICK MULTIPLE LIGHT BEAM SAFETY DEVICES

获取价格

1018176 SICK MULTIPLE LIGHT BEAM SAFETY DEVICES

获取价格

1018177 SICK MULTIPLE LIGHT BEAM SAFETY DEVICES

获取价格

1018178 SICK MULTIPLE LIGHT BEAM SAFETY DEVICES

获取价格