HIGH PERFORMANCE
KENSERIES IEC INLET SNAP-IN FILTERS
V
D
E
INTRODUCTIONS
SPECIFICATIONS
1. Applications for UL 544 & UL 2601 health care equipment.
2. Specially designed with ground choke providing most effective
EMI suppression for high frequency noise (ranged 5MHz-25MHz).
3. Bleeder resistor can be added with suffix "-R" on part numbers.
4. With optional 0.1uF X capacitor instead of 0.047uF.
1. Maximum leakage current each
line-to-ground @ 115VAC 60Hz: 2uA
@ 250VAC 50Hz: 5uA
2. Hipot rating (one minute)
line-to-ground: 2250VDC
line-to-line: 1450VDC
5. With optional solder lug connection instead of fast on terminal.
3. Operating frequency: 50/60Hz
4. Rated voltage: 115/250VAC
COMPONENTS
PART NO.
L (mH) Cx (uF) Lg (uH)
03KENG3DAM/03KENW3DAM
03KENG3EAM/03KENW3EAM
08KENG3DAM/08KENW3DAM
08KENG3EDAM/08KENW3EAM
10KENG3DAM/10KENW3DAM
10KENG3EAM/10KENW3EAM
3.1
3.1
0.8
0.8
0.4
0.4
0.047
0.1
ELECTRICAL SCHEMATIC
0.047
0.1
*
100
*
0.047
0.1
**
**
L
L'
L
I
L
O
A
D
R
Cx
** UL, CSA & VDE approved to 9A 115/250VAC
* VDE approved to 6A 250V
L
N
E
N
G
N'
G'
MINIMUM INSERTION LOSS IN dB
Lg
COMMON MODE (L-G) IN 50 OHM SYSTEM
R: 1M /-R ONLY
FREQUENCY-MHz
CURRENT
RATING
.15
20
10
5
.50
30
12
10
1.0
30
15
12
5.0
30
15
12
10
25
15
12
30
10
10
10
3A
8A
10A
DIFFERENTIAL MODE (L-L) IN 50 OHM SYSTEM
3A
8A
0
0
0
10
10
10
12
12
12
25
25
25
25
25
25
20
20
20
1
2
10A
5
1.22 0.02
31.5 0.5
MECHANICAL CONSTRUCTION
R0.08MAX.
R2.0MAX.
+0.012
-0
1.12
0.04~0.063
1.0~1.6
+0.3
-0
28.45
SUGGESTED MOUNTING CUTOUT
SUGGESTED THICKNESS OF
MOUNTING PANEL IS FROM
0.04 (1.0) TO 0.063 (1.6)
G
4
3
1.12 MAX.
28.4 MAX.
INCH (MM) OF MOUNTING CUTOUT
G3DAM
1
2
5
1.22 0.02
31.5 0.5
R0.08 MAX.
R2.0 MAX.
+0.012
-0
1.12
0.04~0.063
1.0~1.6
+0.3
-0
28.45
SUGGESTED MOUNTING CUTOUT
1.12 MAX.
28.4 MAX.
W3DAM
INCH
mm
UNIT:
ALL WIRE LEADS 4.0" LONG MIN.
7-5