Micro-D Metal Shell - .050" Contact Spacing
MDM
Mounting Hardware Views (for size 100)
This hardware supplied unassembled.
.123 .005
(3.12 0.13) DIA.
#4-40 UNC-2B
THD
+.010
-.005
180
(4.57
#4-40 UNC-2A THD
#4 LOCK WASHER
PANEL -
+.025
-0.13
)
MAY BE USED WITH
.093 (2.36) MAX
THICK PANEL
A
.395 (10.03)
MAX.
.500 (12.70)
MAX.
.185 (4.70)
MAX.
MATING SIDE
#4-40 UNC-2B NOTHING OR FEMALE THD
B
.064 .010
(1.62 0.25) TYP.
Jackpost - (P)
90˚Angle Mounting
Bracket
.235 .005
(5.97 0.13)
Note: Size 100 requires .120 dia (B) mounting hole
when using Commercial (P) jackpost kits.
90° Angle Mounting
Bracket
B
A
Description
Jackpost kit
Mounting Bracket 90˚ MDM
Part Number
320-9505-015
015-9528-000
Max.
.005 (0.13)
N/A
.191 (4.85)
.370 (9.40)
This hardware is factory installed.
MATING
FACE
.014 .004
.735 (18.67)
MAX.
(0.36 0.10) ALLOWABLE
CONNECTOR
SHOWN FOR
REF. ONLY
DIAMETRAL FLOAT
.020 (0.51) MAX. ALLOWABLE
AXIAL FLOAT
.174 .005
(4.4 .10)
HEX. SOCKET HEAD.
.078 (1.98) ACROSS FLATS
.050 (1.27) MIN. DEPTH
.185 (4.70)
.155 (3.94) MAX.
.093
(2.36)
REF.
MAX
.040 (1.02) MAX.
AXIAL FLOAT
.116 .002
(2.29 .051)
DIA
.031 .003
PART HAS A .040 (1.02)
MAX AXIAL FLOAT
#4-40
UNC-2A
THD
MATING
FACE
(0.79 0.08)
#4-40 UNC-2A THD
MATING SIDE
Jackscrew - (K) Standard
Float Mount - (F) Std.
Jackscrew - (L) (Low Profile)
*NOTE: Torque values are as follows:
Low Profile Jackscrew (L)-4.0 in-lbs
Standard Profile Jackscrew (K)-4.0 in-lbs
Jackpost Bushing (for Rear Panel Mounting)
Dimensions for Rear Panel Mounting
ENGAGING FACE
3/16" HEX.
LOCKING POST
1.800 .005
(45.72 0.13)
#4-40 UNC-2B
.185 (4.70)
.170 (4.32)
+.004
-.000
.401
A
A
)
+1.10
-0.00
(10.18
Panel
+.005 (0.13)
-.000 (0.00)
Jackpost Kit
Number*
.500 (12.70)
MAX.
Thickness
.161 (4.09)
.159 (4.04)
+.004
DIA.
1.516
-.000
3/32 (2.4)
1/16 (1.6)
1/32 (0.8)
3/64 (1.2)
.087 (2.21)
.058 (1.42)
.025 (0.64)
.042 (1.07)
320-9505-013
320-9505-012
320-9505-010
320-9505-011
+1.10
-0.00
)
(38.51
RECEPTACLE SHOWN
FOR REF. ONLY
+.005
-.000
.125
R
)
+0.13
-0.00
(3.18
#4-40 THREAD
RETAINING NUT
*2 jackposts, 2 nuts, 2 washers
Torque value for size 100
Note: Size 100 requires B mounting hole shell
size when using rear panel mount jackposts
Dimensions shown in inch (mm)
Specifications and dimensions subject to change
www.ittcannon.com
14