(1/2)
Conformity to RoHS Directive
EMC Filters for AC Power Line
Inlet-socket Type ZUG-13AS Series
FEATURES
SAFETY STANDARDS
Standard and standard No.
• This inlet-socket type EMC filter prevent microcomputer opera-
tional errors by use of a common mode choke coil featuring an
amorphous core with exceptional magnetic characteristics.
• Sharply attenuates high voltage pulses entering from the power
supply line. For example, the ZUG2203-13AS achieves over
20dB of attenuation for a 600V, 400ns input pulse.
• Lug type output terminals for soldering.
U.S.A.
Canada
Europe
NEMKO
Part No.
CSA
UL
UL1283
E62388
E62388
CSA C22.2 No.8
LR76849C
LR76849C
EN60939
P08208996
P08208996
ZUG2203-13AS
ZUG2206-13AS
• Compact and low-cost due to use of an insulating plastic case.
• It is a product conforming to RoHS directive.
APPLICATIONS
Personal computers, computer terminals, various types of office
automation equipment, digital devices(ECRs, electronic calcula-
tors, electronic scales, etc.), measurement equipment, medical
equipment, etc. Particularly appropriate for various types of elec-
tronic devices that require miniaturization.
SHAPES AND DIMENSIONS
Typical dimensions for installation
From back side panel
From front panel
ø3.6 or M3 tap
R1
ø3.6
R5.5
Ground
terminal
øH
C
F
E
J
B
23.2
11
20
• Tighten the panel mounting M3 dia. bolt with the torque under 5.88x10-1N • m.
Dimensions in mm
Part No.
ZUG2203-13AS, 2206-13AS
A
50
B
40.2
C
22.5
D
40
E
35
F
5.2
G
30.5
øH
3.3
I
J
8
20
• Case:plastic, input terminal:inlet-socket(EN60320), output terminal: lug terminal
ELECTRICAL CHARACTERISTICS
Part No.
Rated voltage Eac (V)
Rated current (A)
ZUG2203-13AS
250
3
ZUG2206-13AS
250
6
Test voltage Eac (V)[Between terminal and ground terminal]
1500
1500
I
nsulation resistance (M
Ω
)[DC.500V,1min/between terminal and ground terminal] 100min.
100min.
0.5max.
100max.
–25 to +85
55
Leakage current (mA) [250V • 60Hz]
DC resistance(mΩ)
Operating temperature range(°C)[Including self-temperature rise]
With derating over(°C)
0.5max.
150max.
–25 to +85
55
Temperature rise(°C)
Attenuation frequency range
(MHz)[+5 to +35°C]
Pulse attenuation characteristics
Input pulse voltage (kV)∗
Weight (g)
30max.
4 to 30
3 to 30
0.6[10dB]
0.6[20dB]
33
30max.
5 to 30
5 to 30
0.3[10dB]
0.4[10dB]
33
Differential mode 30dB
Common mode 30dB
Differential mode
Common mode
∗Input pulse width:0.4µs
• Conformity to RoHS Directive: This means that, in conformity with EU Directive 2002/95/EC, lead, cadmium, mercury, hexavalent chromium, and specific
bromine-based flame retardants, PBB and PBDE, have not been used, except for exempted applications.
• All specifications are subject to change without notice.
003-01 / 20080818 / e9164_zug_13as.fm