VER : B_0
update : 2012.01.20
LED Power
ZQF30(R) SERIES
30 Watts
KEY FEATURES
Open Frame LED Power Supply
With Constant Current & Constant Voltage (C.C+C.V mode)
Universal Input: 100-240 VAC
With P.F.C. Function, PF>0.9
Free Air Convection
Protections: Over Load / Over Voltage / Short Circuit
High Reliability & Double Layered PCB
Ultra Compact Size: 4.0 x 2.0 x 1.12 Inches
3-Years Product Warranty
ELECTRICAL SPECIFICATIONS
All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Model No.
ZQF30(R)-13.5S
31.4W
ZQF30(R)-24S
33.6W
ZQF30(R)-48S
33.6W
Max output wattage ( W )
Voltage
(Note2)
90-264 VAC
50 / 60 Hz
Frequency (Hz)
Power factor
PF>0.9 at Full load (115 VAC / 230 VAC)
0.4A max. (115 VAC) / 0.2A max. (230 VAC)
40 A max. (Cold Start at 230 VAC)
Input
Current (Full load)
Inrush current
Leakage Current
Voltage (V.DC.)
< 0.7 mA max at 240 VAC / 63 Hz
13.5V
24V
48V
Constant Current Operation Voltage (max) (CC Mode) (Note3)
Voltage Tolerance
11~13.5VDC
±10%
18~ 24VDC
36~ 48VDC
Preset Current (mA) (CC Mode)
Current Adjustment Range (mA) (CC Mode)
Minimum Load (mA)
2100
1400
700
1700 ~ 2330
1700
1050 ~ 1400
1050
525 ~ 700
525
Output
±4%
Line Regulation (115-230VAC) (typ.)
Load Regulation (Min-Max) (typ.)
Ripple & Noise (max)
±5%
2.4Vp-p
85%
2.4Vp-p
88%
4.8Vp-p
89%
Efficiency (at 230VAC.)(typ)
Over current protection
Auto recovery
Zener diode clamp
Auto recovery
3750V
Protection
Isolation
Over voltage protection
Short circuit protection
Input-Output (V.AC)
Input-FG
(V.AC)
1880V
Output-FG .(V.AC)
Operating temperature
Storage temperature
Temperature coefficient
Humidity
500V
-30°C…+70°C (with derating)
-40°C…+85°C
Environment
0.02%/°C
95% RH
MTBF
>583,000 h @ 25°C (MIL-HDBK-217F)
Dimension (L x W x H)
Weight
4.0 x 2.0 x 1.12 Inches ( 101.6 x 50.8 x 28.5 mm ) Tolerance ±0.5 mm
Physical
Safety
165 g
Cooling method
Agency Approvals
Free air convection
IEC / EN 61347-2-13、 IEC / EN 61347-1
EMI
EN 55015
(Conducted & Radiated Emission)
EMC
EMS (Noise Immunity)
Harmonic Current
EN 61547
EN 61000-3-2(at Full Load)、EN 61000-3-3
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-1-