Z01
Tables 4: Electrical Characteristics (Tj = 25°C, unless otherwise specified)
Z01
Symbol
Test Conditions
Quadrant
Unit
03
07
09
10
3
5
5
7
10
10
25
25
IGT (1)
VGT
I - II - III - IV MAX.
mA
V
VD = 12 V RL = 30 Ω
ALL
ALL
MAX.
MIN.
1.3
0.2
VD = VDRM RL = 3.3 kΩ
Tj = 125°C
VGD
V
IH (2)
IT = 50 mA
IG = 1.2 IGT
MAX.
7
7
10
10
20
20
10
15
25
50
25
25
mA
I - III - IV
II
IL
MAX.
mA
15
10
50
VD = 67 %VDRM gate open Tj = 110°C
(dV/dt)c = 0.44 A/ms Tj = 110°C
dV/dt (2)
MIN.
MIN.
100
V/µs
(dI/dt)c (2)
0.5
1
2
5
A/ms
Table 5: Static Characteristics
Symbol
Test Conditions
tp = 380 µs Tj = 25°C
Value
Unit
V
V
TM (2)
ITM = 1.4 A
MAX.
1.56
0.95
400
5
Vto (2)
Rd (2)
Tj = 125°C
Tj = 125°C
Tj = 25°C
Tj = 125°C
Threshold voltage
Dynamic resistance
MAX.
MAX.
V
mΩ
µA
mA
IDRM
IRRM
VDRM = VRRM
MAX.
0.5
Note 1: minimum I
is guaranted at 5% of I
GT
max.
GT
Note 2: for both polarities of A2 referenced to A1.
Table 6: Thermal resistances
Symbol
Parameter
SOT-223
Value
Unit
Rth(j-t)
Rth(j-I)
Junction to tab (AC)
Junction to lead (AC)
Junction to ambient
25
60
°C/W
TO-92
²
SOT-223
TO-92
60
S = 5 cm
Rth(j-a)
°C/W
150
S = Copper surface under tab.
2/8