Specifications
■ Characteristics
Z-15
Z-15
(flexible rod)
Classification
(except micro load
and flexible rod)
Z-01H
Z-10F
Z-15H2
Item
Operating speed
0.01 mm to 1 m/s (*1)
240 operations/min
20 operations/min
1 mm to 1 m/s
120 operations/min
0.1 mm to 1 m/s (*1)
240 operations/min
0.01 mm to 1 m/s
240 operations/min
Mechanical
Electrical
Operating
frequency
15 m
Ω
max. (initial value) 50 m
Ω
max. (initial value) 15 mΩ max. (initial value)
25 mΩ max. (initial value) 15 mΩ max. (initial value)
Contact resistance
100 MΩ min. (at 500 VDC)
Insulation resistance
Between contacts of same polarity
Contact gap G: 1,000 VAC
Contact gap H: 600 VAC
Between contacts of same polarity Between contacts of
Between contacts of
same polarity
Contact gap G: 1,000 VAC
Contact gap H: 600 VAC
same polarity
Contact gap F: 1,500 VAC 600VAC
Dielectric strength
(50 / 60 Hz for 1 min.)
Contact gap E: 1,500 VAC
Between current-carrying metal parts and ground, and between each terminal and non-current-carrying metal parts:
2,000 VAC
10 to 55 Hz, 1.5-mm double amplitude (*5)
10 to 20 Hz, 1.5-mm double amplitude (*5) 10 to 55 Hz, 1.5-mm double amplitude (*5)
Vibration
resistance
Malfunction
Destruction 1,000 m/s2 max.
Malfunction 300 m/s2 max. (*2, *5)
Shock
resistance
50 m/s2 max. (*5)
300 m/s2 max. (*3, *5) 100 m/s2 max.
IP00
General-
purpose
Degree of
protection
Equivalent to IP62 (except terminals)
Class I
Drip-proof
Degree of protection
against electric shock
175
Proof tracking index
(PTI)
−25°C to 80°C (with no icing)
General-
Ambient
purpose
operating
temperature
−15°C to 80°C (with no icing)
Drip-proof
35% to 85%RH
General-
purpose
Ambient
operating
humidity
35% to 95%RH
Drip-proof
Contact gap H2: 10,000,000 operations min.
Contact gap G, H: 20,000,000 operations min.(*4)
Contact gap E: 300,000 operations
1,000,000 operations min.
500,000 operations min. (*1) 20,000,000 operations min.
100,000 operations min. 500,000 operations min.
Mechanical
Service life
Weight
Contact gap G, H: 500,000 operations min.
Contact gap E: 100,000 operations min.
100,000 operations min.
Approx. 42 to 48 g
Electrical
Approx. 22 to 58 g
Approx. 34 to 61 g
Approx. 22 g
*1 The values are for the plunger models. (For the lever models, the values are
at the plunger section.)
*2 The values are for the Z-15G pin plunger.
*3 The values are for the Z-10FY-B.
*4 The values are for the pin plunger. The service life for models other than the
pin plunger is 10,000,000 min.
*5 Malfunction: 1 ms max.
■ Ratings (Basic, Split-contact and Maintained contact Models)
Z-15 (Except Micro Load and Flexible Rod Models)
Non-inductive load (A)
Resistive load Lamp load
NC NO
Inductive load (A)
Inductive load
NC NO
Item
Motor load
Contact gap
Rated voltage
125 VAC
NC
3
NO
1.5
1.25
0.75
1.5
1.5
1.5
0.5
0.25
1.5
1.5
1.4
0.4
0.2
1.5
1.5
1.5
0.75
0.3
NC
5
NO
2.5
1.5
0.75
2.5
2.5
2.5
0.05
0.03
2.5
2.5
1
0.03
0.02
2.5
2.5
2.5
0.4
0.2
15 (10) *
15 (10) *
10
15 (10) *
15 (10) *
6
G, H, H2, E 250 VAC
500 VAC *
2.5
1.5
3
3
1.5
8 VDC
14 VDC
15
15
5
15
3
10
5
G
H, H2
E
30 VDC
125 VDC
250 VDC
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
6
3
5
5
0.5
0.25
15
0.5
0.25
3
0.05
0.03
15
0.05
0.03
5
15
3
10
5
2
2
1
1
0.4
0.2
15
0.4
0.2
3
0.03
0.02
15
0.03
0.02
5
15
3
15
5
15
3
10
5
0.75
0.3
0.75
0.3
0.4
0.2
0.4
0.2
* Figures in parentheses are for the Z-15HW52, Z-15HW78(-B) and Z-15H2(-B) models, the AC ratings of these models are 125 and 250 V only.
152
General-purpose Basic Switch Z