描述
Dual Digitally Controlled Potentiometers

X93256 数据手册

 浏览型号X93256的Datasheet PDF文件第3页浏览型号X93256的Datasheet PDF文件第4页浏览型号X93256的Datasheet PDF文件第5页浏览型号X93256的Datasheet PDF文件第6页浏览型号X93256的Datasheet PDF文件第8页浏览型号X93256的Datasheet PDF文件第9页 
X93256  
PIN DESCRIPTIONS  
(In the text, CS, INC, U/D, R , R , and R are used to  
PRINCIPLES OF OPERATION  
H
W
L
There are multiple sections for each potentiometer in the  
X93256: an input control, a counter and decode section;  
the nonvolatile memory; and a resistor array. Each input  
control section operates just like an up/down counter.  
The output of this counter is decoded to turn on a single  
electronic switch connecting a point on the resistor array  
to the wiper output. Under the proper conditions the  
contents of the counter can be stored in nonvolatile  
memory and retained for future use. Each resistor array  
is comprised of 31 individual resistors connected in  
series. At either end of the array and between each  
resistor is an electronic switch that transfers the  
connection at that point to the wiper.  
refer to either CS or CS , etc. Note: These signals can  
1
2
be applied independently or at the same time.)  
R and R  
H
L
The R and R pins of the X93256 are equivalent to the  
H
L
fixed terminals of a mechanical potentiometer. The  
minimum voltage is V and the maximum is V . The  
SS  
CC  
terminology of R and R references the relative position  
H
L
of the terminal in relation to wiper movement direction  
selected by the U/D input per potentiometer.  
R
W
The R pin of the X93256 is the wiper terminal of the  
potentiometer which is equivalent to the movable terminal of  
a mechanical potentiometer  
W
Each wiper, when at either fixed terminal, acts like its  
mechanical equivalent and does not move beyond the  
last position. That is, the counter does not wrap around  
when clocked to either extreme.  
Up/Down (U/D)  
The U/D input controls the direction of a single  
potentiometer’s wiper movement and whether the  
counter is incremented or decremented.  
If the wiper is moved several positions, multiple taps are  
connected to the wiper for t (INC to V change). The  
IW  
W
2-terminal resistance value for the device can temporarily  
change by a significant amount if the wiper is moved  
several positions.  
Increment (INC)  
The INC input is negative-edge triggered. Toggling INC  
will move the wiper and either increment or decrement  
the pertatining potentiometer’s counter in the direction  
indicated by the logic level on the pertaining  
potentiometer’s U/D input.  
When the device is powered-down, the last wiper  
position stored will be maintained in the nonvolatile  
memory for each potentiometer. When power is  
restored, the contents of the memory are recalled and  
each wiper is set to the value last stored.  
Chip Select (CS)  
A potentiometer is selected when the pertaining CS input  
is LOW. Its current counter value is stored in nonvolatile  
memory when the pertaining CS is returned HIGH while  
the pertaining INC input is also HIGH. After the store  
operation is complete the affected potentiometer will be  
placed in the low power standby mode until the  
potentiometer is selected once again.  
FN8188.0  
7
March 4, 2005  

与X93256相关器件

型号 品牌 描述 获取价格 数据表
X93256_06 INTERSIL Dual Digitally Controlled Potentiometers

获取价格

X93256_08 INTERSIL Dual Digitally Controlled Potentiometers(XDCPs?)

获取价格

X93256UV14I-2.7 INTERSIL Dual Digitally Controlled Potentiometers

获取价格

X93256UV14IZ-2.7 INTERSIL Dual Digitally Controlled Potentiometers

获取价格

X93256WV14I-2.7 INTERSIL Dual Digitally Controlled Potentiometers

获取价格

X93256WV14I-2.7T1 RENESAS DUAL 12.5K DIGITAL POTENTIOMETER, INCREMENT/DECREMENT CONTROL INTERFACE, 32 POSITIONS, PDS

获取价格