X93254
ABSOLUTE MAXIMUM RATINGS
COMMENT
Temperature under bias.................... -65°C to +135°C
Storage temperature ......................... -65°C to +150°C
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only; the functional operation of
the device (at these or any other conditions above
those listed in the operational sections of this specifi-
cation) is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect
device reliability.
Voltage on CS, INC, U/D, R , R and V
H
L
CC
with respect to V .............................. -1V to +6.5V
SS
Lead temperature (soldering 10 seconds)......... 300°C
Maximum reflow temperature (40 seconds) ...... 240°C
Maximum resistor current.....................................2mA
RECOMMENDED OPERATING CONDITIONS
Temperature
Min.
Max.
Supply Voltage (V
)
Limits
CC
(7)
Industrial
-40°C
+85°C
X93254
3V ± 10%
POTENTIOMETER CHARACTERISTICS (Over recommended operating conditions unless otherwise stated.)
Limits
Symbol
Parameter
Min.
37.5
0
Typ.
Max.
Unit
kΩ
V
Test Conditions/Notes
R
End to end resistance
50
62.5
(5)
(5)
TOT
V
R , R terminal voltages
V
R
H
L
CC
1
(6)
(5)
Power rating
Noise
mW
dBV
Ω
R
= 50kΩ
TOTAL
(6)
(5)
-120
3
Ref: 1kHz
(5) (6)
(5) (6)
(5)
R
Wiper Resistance
Wiper Current
Resolution
1000
0.6
W
I
mA
%
W
(1)
(3)
(5)
Absolute linearity
(2)
±1
MI
MI
V
V
- V
H(n)(actual)
H(n)(expected)
(5)
(3)
Relative linearity
temperature coefficient
±0.5
- [V
H(n+1)
H(n)+MI
R
±35
ppm/°C (5) (6)
pF
TOTAL
(5)
C /C /C
W
Potentiometer capacitances
10/10/25
See circuit #2
H
L
Notes: (1) Absolute linearity is utilized to determine actual wiper voltage versus expected voltage = (V
Maximum. n = 1 .. 29 only
(actual) - V
(expected)) = ±1 Ml
H(n)
H(n)
(2) Relative linearity is a measure of the error in step size between taps = V
- [V
+ Ml] = ±0.5 Ml, n = 1 .. 29 only.
H(n)
H(n+1)
(3) 1 Ml = Minimum Increment = R
/31.
TOT
(4) Typical values are for T = 25°C and nominal supply voltage.
A
(5) This parameter only applies to a single potentiometer.
(6) This parameter is guaranteed by characterization.
(7) When performing multiple write operations, V
must not decrease by more than 150mV from its initial value.
CC
FN8186.0
3